SIEMENS
2/604
Siemens IK PI · 2015
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1613 A2
2
■
Integration
System configuration with CP 1613 A2/CP 1623/CP 1628
and HARDNET-IE S7
Example of redundant network structure with
CP 1613 A2/CP 1623/CP 1628 and HARDNET-IE S7-REDCONNECT
■
Technical specifications
S7-300 with
CP 343-1 Lean,
CP 343-1,
CP 343-1
Advanced
S7-400 with
CP 443-1,
CP 443-1
Advanced
PC/IPC with CP 1613 A2/
CP 1623/CP 1628 and
HARDNET-IE S7
S7-1500 with
CP 1543-1
CM 1542-1
S7-1200 with
CP 1243-1
Industrial
Ethernet
G_IK10_XX_10250
PC with
2 x CP 1613 A2/CP 1623/CP 1628
and HARDNET-IE
S7-REDCONNECT
H CPU
in single mode
S7-400H
ET 200M
Industrial Ethernet
G_IK10_XX_10048
PROFIBUS
Article No.
6GK1161-3AA01
Product-type designation
CP 1613 A2
Transmission rate
Transfer rate at the interface 1
10 … 100 Mbit/s
Interfaces
Number of electrical connections
at interface 1 in accordance
with Industrial Ethernet
2
Design of electrical connection
• at interface 1 in accordance
with Industrial Ethernet
RJ45 port / 15-pin ITP connection
• of the backplane bus
PCI (32 Bit 3.3 V/5 V UniversalKey
33/66 MHz)
Supply voltage,
current consumption, power loss
Type of supply voltage
DC
Supply voltage
• 1 from backplane bus
5 V
• 2 from the backplane bus
12 V
Relative symmetrical tolerance
• at 5 V with DC
5 %
• at 12 V with DC
5 %
Consumed current
• 1 from backplane bus
with DC maximum
0.45 A
• 2 from backplane bus
with DC maximum
0.5 A
Resistive loss
4 W
Permitted ambient conditions
Ambient temperature
• during operating
5 … 55 °C
• during storage
-20 … +60 °C
• during transport
-20 … +60 °C
Relative humidity at 25 °C without
condensation during operating
maximum
95 %
Protection class IP
IP00
Design, dimensions and weight
Module format
PCI
Width
21.6 mm
Height
107 mm
Depth
167 mm
Net weight
140 g
Product properties, functions,
components
general
Number of plug-in cards
in the same design can be plugged
in per PC station
4
© Siemens AG 2014