SIEMENS
2/600
Siemens IK PI · 2015
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1612 A2
2
■
Technical specifications
Article No.
6GK1161-2AA01
Product-type designation
CP 1612 A2
Transmission rate
Transfer rate at the interface 1
10 … 1 000 Mbit/s
Interfaces
Number of electrical connections
at interface 1 in accordance
with Industrial Ethernet
1
Design of electrical connection
• at interface 1 in accordance
with Industrial Ethernet
RJ45 port
• of the backplane bus
PCI (32 Bit 3.3 V/5 V UniversalKey
33/66 MHz)
Supply voltage,
current consumption, power loss
Type of supply voltage
DC
Supply voltage
• 1 from backplane bus
5 V
• 2 from the backplane bus
12 V
Relative symmetrical tolerance
• at 5 V with DC
5 %
• at 12 V with DC
5 %
Consumed current
• 1 from backplane bus
with DC maximum
0.45 A
• 2 from backplane bus
with DC maximum
0.5 A
Resistive loss
3.65 W
Permitted ambient conditions
Ambient temperature
• during operating
0 … 55 °C
• during storage
-10 … +70 °C
• during transport
-10 … +70 °C
Relative humidity at 25 °C without
condensation during operating
maximum
95 %
Protection class IP
IP00
Design, dimensions and weight
Module format
PCI
Width
18 mm
Height
59 mm
Depth
140 mm
Net weight
60 g
Product properties, functions,
components
general
Number of plug-in cards
in the same design can be plugged
in per PC station
2
Performance data
Performance data
open communication
Software for open communication
by means of SEND/RECEIVE
required
Yes, SOFTNET-IE S7 (64 conn.) /
SOFTNET-IE S7 Lean (8 conn.)
Number of possible connections
for open communication
by means of SEND/RECEIVE
maximum
64
Performance data
S7 communication
Software for S7 communication
required
Yes, SOFTNET-IE S7 (64 conn.) /
SOFTNET-IE S7 Lean (8 conn.)
Number of possible connections for
S7/PG communication maximum
64
Performance data
multi-protocol mode
Number of active connections
with multiprotocol mode
64
Number of configurable connections
per PC station
207
Performance data
PROFINET communication
as PN IO-Controller
Software for PROFINET IO
communication required
Yes, SOFTNET-IE PN IO
Number of PN IO-Devices on
PROFINET IO-Controller usable total
64
Number of PN IO IRT-Devices on
PROFINET IO-Controller usable
0
Data volume
• as useful data for input variables
as PROFINET IO controller
maximum
4 096 byte
• as useful data for output variables
with PROFINET IO controller
maximum
4 096 byte
• as useful data for input variables
per PN IO device with PROFINET IO
controller maximum
1 472 byte
• as useful data for output variables
per PN IO device with PROFINET IO
controller maximum
1 472 byte
Performance data
PROFINET CBA
Software for PROFINET CBA
communication required
Yes, PN CBA OPC server
Number of remote connection
partners with PROFINET CBA
228
Number of connections
with PROFINET CBA total
10 000
Article No.
6GK1161-2AA01
Product-type designation
CP 1612 A2
© Siemens AG 2014