CP 1616
2
■
Technical specifications
Article No.
6GK1161-6AA02
Product-type designation
CP 1616
Transmission rate
Transfer rate at the interface 1
10 … 100 Mbit/s
Interfaces
Number of electrical connections
• at interface 1 in accordance
with Industrial Ethernet
4
• for power supply
1
Design of electrical connection
• at interface 1 in accordance
with Industrial Ethernet
RJ45 port
• of the backplane bus
PCI (32 Bit 3,3 V/5 V UniversalKey
33/66 MHz)
• for power supply
Low-voltage socket for hollow plug
3.5 mm (-) / 1.3 mm (+)
Supply voltage,
current consumption, power loss
Type of supply voltage
DC
Type of power supply optional
external supply
Yes
Supply voltage
• 1 from backplane bus
5 V
• external
6 … 9 V
Relative symmetrical tolerance
at 5 V with DC
5 %
Consumed current
• 1 from backplane bus
with DC maximum
0.8 A
• from external supply voltage
-
at 9 V with DC max.
0.65 A
-
at 9 V with DC max.
0.45 A
Resistive loss
4 W
• in switch mode maximum
4.1 W
Permitted ambient conditions
Ambient temperature
• during operating
5 … 70 °C
• during storage
-40 … +70 °C
• during transport
-20 … +60 °C
Relative humidity at 25 °C without
condensation during operating
maximum
95 %
Protection class IP
IP00
Design, dimensions and weight
Module format
PCI
Width
18 mm
Height
107 mm
Depth
167 mm
Net weight
110 g
Product properties, functions,
components
general
Number of plug-in cards
in the same design can be plugged
in per PC station
1
Performance data
Performance data
PROFINET communication
as PN IO-Controller
Software for PROFINET IO
communication required
No
Number of PN IO-Devices on
PROFINET IO-Controller usable total
128
Number of PN IO IRT-Devices on
PROFINET IO-Controller usable
64
Data volume
• as useful data for input variables
as PROFINET IO controller
maximum
8 192 byte
• as useful data for output variables
with PROFINET IO controller
maximum
8 192 byte
• as useful data for input variables
per PN IO device with
PROFINET IO controller maximum
1 433 byte
• as useful data for output variables
per PN IO device with
PROFINET IO controller maximum
1 433 byte
Performance data
PROFINET communication
as PN IO-Device
Amount of data
• as useful data for input variables
as PROFINET IO device maximum
1 433 byte
• as useful data for input variables
as PROFINET IO device maximum
1 433 byte
• as useful data for input variables
for each sub-module under
PROFINET IO device
254 byte
• as useful data for input variables
for each sub-module under
PROFINET IO device
254 byte
• as useful data for the consistency
area for each sub-module
254 byte
Number of submodules
per PROFINET IO-Device
64
Product functions
management,
configuration
Product function MIB support
Yes
Protocol is supported
• SNMP v1
Yes
• DCP
Yes
• LLDP
Yes
Configuration software required
included in scope of delivery
Identification & maintenance function
• I&M0 - device-specific information
Yes
• I&M1 - higher level designation/loca-
tion designation
Yes
• I&M2 - installation date
Yes
• I&M3 - comment
Yes
• I&M4 - signature
Yes
Article No.
6GK1161-6AA02
Product-type designation
CP 1616
© Siemens AG 2014