SIEMENS
2/593
Siemens IK PI · 2015
PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1604
2
■
Technical specifications
Article No.
6GK1160-4AA01
Product-type designation
CP 1604
Transmission rate
Transfer rate at the interface 1
10 … 100 Mbit/s
Interfaces
Number of electrical connections
• at interface 1 in accordance
with Industrial Ethernet
4
• for power supply
1
Design of electrical connection
• at interface 1 in accordance
with Industrial Ethernet
RJ45 port via connection board
• of the backplane bus
PCI-104 (32Bit)
• for power supply
4-pin terminal block
via power supply board
Supply voltage,
current consumption, power loss
Type of supply voltage
DC
Type of power supply optional
external supply
Yes
Supply voltage
• 1 from backplane bus
5 V
• external
24 V
• note
optional external power supply and
external supply voltage alternatively
via power supply board (optional
accessory)
Relative symmetrical tolerance
• at 5 V with DC
5 %
• at 24 V with DC
20 %
Consumed current
• 1 from backplane bus
with DC maximum
0.8 A
• from external supply voltage
at 24 V with DC maximum
0.3 A
Resistive loss
4 W
• in switch mode maximum
4.1 W
Permitted ambient conditions
Ambient temperature
• during operating
5 … 60 °C
• during storage
-20 … +60 °C
• during transport
-20 … +60 °C
Relative humidity at 25 °C without
condensation during operating
maximum
95 %
Protection class IP
IP00
Design, dimensions and weight
Module format
PC/104-Plus
Width
90 mm
Height
24 mm
Depth
95 mm
Net weight
110 g
Product properties, functions,
components
general
Number of plug-in cards
in the same design can be plugged
in per PC station
1
Performance data
Performance data
PROFINET communication
as PN IO-Controller
Software for PROFINET IO
communication required
No
Number of PN IO-Devices on
PROFINET IO-Controller usable total
128
Number of PN IO IRT-Devices on
PROFINET IO-Controller usable
64
Data volume
• as useful data for input variables as
PROFINET IO controller maximum
8 192 byte
• as useful data for output variables
with PROFINET IO controller
maximum
8 192 byte
• as useful data for input variables
per PN IO device with PROFINET IO
controller maximum
1 433 byte
• as useful data for output variables
per PN IO device with PROFINET IO
controller maximum
1 433 byte
Performance data
PROFINET communication
as PN IO-Device
Amount of data
• as useful data for input variables
as PROFINET IO device maximum
1 433 byte
• as useful data for input variables
as PROFINET IO device maximum
1 433 byte
• as useful data for input variables
for each sub-module under
PROFINET IO device
254 byte
• as useful data for input variables
for each sub-module under
PROFINET IO device
254 byte
• as useful data for the consistency
area for each sub-module
254 byte
Number of submodules per
PROFINET IO-Device
64
Product functions
management,
configuration
Product function MIB support
Yes
Protocol is supported
• SNMP v1
Yes
• DCP
Yes
• LLDP
Yes
Configuration software required
included in scope of delivery
Identification & maintenance function
• I&M0 - device-specific information
Yes
• I&M1 - higher level designation/loca-
tion designation
Yes
• I&M2 - installation date
Yes
• I&M3 - comment
Yes
• I&M4 - signature
Yes
Article No.
6GK1160-4AA01
Product-type designation
CP 1604
© Siemens AG 2014