SIEMENS
2/784
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC647D
1)
Memory information: In order to use a memory with more than 4 GB,
a 64-bit operating system is required. In the case of configurations with at
least 4 GB, the visible memory can be reduced to about 3.5 GB or less
(with 32-bit operating systems)
2)
Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX"
(LINUX is a trademark of Linus Torvalds).
3)
SATA RAID controller on board in Intel chipset
4)
Hard disk alarm in conjunction with RAID and monitoring software
Note regarding SIMATIC PC operating system licenses
The accompanying operating system license is only valid for
installation on the respective supplied SIMATIC IPC.
Installation can only be performed on these SIMATIC systems
in accordance with Microsoft OEM licensing regulations.
Monitoring functions
Basic functionality
Message locally via DiagBase
software
Temperature
• Overshoot/undershoot of permissi-
ble operating temperature range
• Messages can be evaluated by the
application program
Fan
• Speed monitoring
• 2 x enclosure fans
• 1 x fan power supply
Watchdog
• Monitoring of program execution
• Monitoring time can be parameter-
ized in software
•
Restart can be parameterized in the
event of a fault
• Messages can be evaluated by the
application program
Monitoring functions via the network
SIMATIC PC DiagMonitor (optional)
Remote monitoring capability for:
• Watchdog
• Temperature
• Fan speed
• Hard disk monitoring (SMART)
• System/Ethernet monitoring
(heartbeat)
Communication:
• Ethernet interface (SNMP protocol)
• OPC for integration in SIMATIC
software
• Configuration of client/server
architectures, configuration of log
files
Front LEDs
• POWER (internal power supply unit,
PC switched on)
• HDD (access to hard disk)
• ETHERNET1
(Ethernet status, "heartbeat")
• ETHERNET2
(Ethernet status, "heartbeat")
• PROFIBUS/MPI (PROFIBUS status)
• SF PROFINET (PROFINET status)
• WATCHDOG (ready/fault indication)
• TEMP (temperature status)
• FAN (fan speed monitoring)
• HDD0 ALARM
4)
• HDD1 ALARM
4)
Ambient conditions
Degree of protection
IP41 at the front,
IP20 at the rear acc. to EN 60529
Dust protection
with front door closed: G2 EN 779,
99 % of particles > 0.5 mm are held
back
Protection class
Protection class I
according to IEC 61140
Vibration load during operation
DIN EN 60068-2-6, 10 cycles
Internal mounting of the hard disk
drives in optional, internal drive cage:
• 10 ... 58 Hz: 0.0375 mm;
•
58
...
500
Hz: 5
m/s2 (approx. 0.5
g)
Note:
There are limitations when DVD+/-RW
and HDD are operated in a remov-
able drive bay
Shock loading during operation
DIN EN 60068-2-27, IEC 60068-2-29
Internal mounting of the hard disk
drives in optional, internal drive cage:
• Half-sine: 50 m/s
2
, 30 ms
(approx. 5 g), 100 shocks per axis
Note:
There are limitations when DVD+/-RW
and HDD are operated in a remov-
able drive bay
SIMATIC IPC647D
Electromagnetic compatibility
(EMC)
Emitted interference (AC)
• EN 61000-6-3, FCC Class A
• EN 61000-6-4; CISPR 22, EN 55022
Class B
• EN 61000-3-2 Class D,
EN 61000-3-3
Immunity to conducted interference
on the supply lines
• ± 2 kV (IEC 61000-4-4, burst)
• ± 1 kV
(IEC 61000-4-5, symm. surge)
• ± 2 kV
(IEC 61000-4-5, asymm. surge)
Noise immunity on signal lines
• ± 1 kV (IEC 61000-4-4, burst,
length < 30 m)
• ± 2 kV (IEC 61000-4-4, symm.
surge, length > 30 m)
• ± 2 kV (IEC 61000-4-5, asymm.
surge, length > 30 m)
Immunity to static discharge
• ± 6 kV, contact discharge
(IEC 61000-4-2)
• ± 8 kV, air discharge
(IEC 61000-4-2)
Immunity to high radio frequency
interference
• 10 V/m, 80 to 1000 MHz and
1.4 to 2 GHz, 80% AM
(according to IEC 61000-4-3)
• 3 V/m, 2 to 2.7 GHz, 80% AM
(according to IEC 61000-4-3)
• 10 V, 10 kHz to 80 MHz, 80% AM
(according to IEC 61000-4-6)
Immunity to magnetic fields
100 A/m, 50/60 Hz (IEC 61000-4-8)
Ambient temperature during
operation
5 … 50 °C
Note:
Limitations for operation of
DVD+/-RW
Humidity during operation
5 ... 85 % at 30 °C (no condensation)
Approvals and safety regulations
Safety regulations
• IEC 60950-1
• EN 60950-1
• UL 60950-1
• CSA C22.2 No 60950-1-07
Approvals
cULus 60950, KCC
CE mark
For use in industrial areas as well as
domestic, business and commercial
environments:
• Emitted interference:
EN 61000-6-3: 2007 +A1:2011
• Noise immunity:
EN 61000-6-2:2005
Dimensions and weights
Installation dimensions
(W x H x D) in mm
430 x 88 x 445
SIMATIC IPC647D
© Siemens AG 2014