SIEMENS
2/779
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Industrial PC
Rack PC
SIMATIC IPC547D
1)
Memory information:
In order to use a memory with more than 4 GB, a 64-bit operating system
is required. In the case of configurations with 4 GB, the visible memory can
be reduced to about 3.5 GB or less (with 32-bit operating systems).
In configurations with 8 GB, the visible memory can be reduced to about
7.5 GB or less.
2)
SATA RAID controller onboard in Intel Q67 chipset
3)
Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
(LINUX is a trademark of Linus Torvalds).
4)
Restrictions in use of optical drives and HDD in removable drive bays.
Note regarding SIMATIC PC operating system licenses
The accompanying operating system license is only valid
for installation on the respective supplied SIMATIC IPC.
Installation can only be performed on these SIMATIC systems
in accordance with Microsoft OEM licensing regulations.
Monitoring functions
Basic functionality
Message locally via DiagBase
software
Temperature
When permitted operating tempera-
ture range is exceeded
Fan
Speed monitoring
• 1 x front fan
• 1 x CPU fan
• 1 x power supply fan
Watchdog
• Monitoring of program execution
• Monitoring time can be parameter-
ized in software
Monitoring functions via the network
SIMATIC IPC DiagMonitor Version
V4.3.x.x or higher (optional)
Remote monitoring capability for:
• Watchdog
• Temperature
• Fan speed
• Battery
• Hard disks (SMART)
• System/Ethernet
Communication:
• Ethernet interface (SNMP protocol)
• OPC for integration in SIMATIC
software
• Client server architecture
• Structure of log files
Front LEDs
• POWER (PC switched on)
• HDD (access to hard disk)
• TEMP (temperature monitoring)
• FAN (fan monitoring)
Additional HDD alarm LEDs for RAID
configurations behind the front flap
Environmental conditions
Degree of protection
IP30 front, IP20 rear
according to EN 60529
Dust protection
With the front door closed
according to IEC 60529 filter class
G2 EN 779, 99% of particles >
0.5 mm are filtered
Protection class
Protection class I
according to IEC 61140
Vibration load during operation
4)
IEC 60068-2-6, 10 cycles
• 20 ... 58 Hz: 0.015 mm
• 58 ... 200 Hz: 2 m/s
2
(approx. 0.2 g)
Shock load in operation
4)
IEC 60068-2-27
• Half-sine: 9.8 m/s
2
, 20 ms
(approx. 1 g), 100 shocks per axis
SIMATIC IPC547D
Electromagnetic compatibility
(EMC)
Emitted interference
EN 61000-6-3; EN 61000-6-4;
CISPR 22 / EN 55022 Class B;
FCC Class A; EN 61000-3-2 Class D;
EN 61000-3-3
Immunity to conducted interference
on the supply lines
• ± 2 kV (IEC 61000-4-4, burst)
• ± 1 kV
(IEC 61000-4-5, symm. surge)
• ±2 kV
(IEC 61000-4-5, asymm. surge)
Noise immunity on signal lines
• ±2 kV (IEC 61000-4-4, burst,
length > 30 m)
• ± 1 kV (IEC 61000-4-4, Burst,
Length < 30 m),
• ± 2 kV (IEC 61000-4-5, Surge,
Length > 30 m)
Immunity to static discharge
• ±4 kV, contact discharge
(IEC 61000-4-2)
• ±8 kV, air discharge
(IEC 61000-4-2)
Immunity to high radio frequency
interference
• 1 V/m 80% AM; 2 ... 2.7 GHz
(IEC 61000-4-3)
• 10 V/m 80% AM;
80 MHz ... 1 GHz and
1.4 GHz … 2 GHz (IEC 61000-4-3);
• 10 V, 10 kHz ... 80 MHz
(IEC 61000-4-6)
Immunity to magnetic fields
100 A/m, 50/60 Hz (IEC 61000-4-8)
Ambient temperature during
operation
5 ... 40 °C
Note:
Limitations for operation of
DVD±R/RW
Humidity during operation
5 ... 80 % at 25 °C (no condensation)
Approvals and safety regulations
Safety regulations
IEC 60950-1; UL60950; CSA
Approvals
cULus 60950
CE mark
For use in industrial areas
as well as domestic, business and
commercial environments:
• Emitted interference:
EN 61000-6-3:2007
• Noise immunity:
EN 61000-6-2:2005
Dimensions and weights
Installation dimensions
(W x H x D) in mm
434 x 177 x 446
Weight, approx.
19 kg
SIMATIC IPC547D
© Siemens AG 2014