SIEMENS
2/340
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300EEC managed
Permitted ambient conditions
Ambient temperature
• during operating
-40 … +70 °C
-40 … +70 °C
-40 … +70 °C
-40 … +70 °C
• during storage
-40 … +85 °C
-40 … +85 °C
-40 … +85 °C
-40 … +85 °C
• during transport
-40 … +85 °C
-40 … +85 °C
-40 … +85 °C
-40 … +85 °C
• Comment
Extended temperature upper
limit of +85° C permitted for
16 hours. Reduced operat-
ing temperature through
the use of media modules
(-40 °C to +70 °C) or
SFP plug-in transceivers
(-40 °C to +60 °C)
Extended temperature upper
limit of +85° C permitted for
16 hours. Reduced operat-
ing temperature through
the use of media modules
(-40 °C to +70 °C) or
SFP plug-in transceivers
(-40 °C to +60 °C)
Extended temperature upper
limit of +85° C permitted for
16 hours. Reduced operat-
ing temperature through
the use of media modules
(-40 °C to +70 °C) or
SFP plug-in transceivers
(-40 °C to +60 °C)
Extended temperature upper
limit of +85° C permitted for
16 hours. Reduced operat-
ing temperature through
the use of media modules
(-40 °C to +70 °C) or
SFP plug-in transceivers
(-40 °C to +60 °C)
Relative humidity at 25 °C without
condensation during operating
maximum
95 %
95 %
95 %
95 %
Protection class IP
IP20
IP20
IP20
IP20
Design, dimensions and weight
Design
19" rack
19" rack
19" rack
19" rack
Width
483 mm
483 mm
483 mm
483 mm
Height
44 mm
44 mm
44 mm
44 mm
Depth
305 mm
305 mm
305 mm
305 mm
Net weight
6.6 kg
6.6 kg
7 kg
7 kg
Mounting type
• 19-inch installation
Yes
Yes
Yes
Yes
• 35 mm DIN rail mounting
No
No
No
No
• wall mounting
No
No
No
No
• S7-300 rail mounting
No
No
No
No
Mounting type
When used in shipbuilding,
the device must be secured
in the 19" rack at four points
When used in shipbuilding,
the device must be secured
in the 19" rack at four points
When used in shipbuilding,
the device must be secured
in the 19" rack at four points
When used in shipbuilding,
the device must be secured
in the 19" rack at four points
Product properties, functions,
components
general
Cascading in the case of a
redundant ring at reconfiguration time
of < 0.3 s
50
50
50
50
Cascading in cases of star structuring
Any
(depending only on signal
propagation time)
Any
(depending only on signal
propagation time)
Any
(depending only on signal
propagation time)
Any
(depending only on signal
propagation time)
Product functions
management,
configuration
Product function
• CLI
Yes
Yes
Yes
Yes
• web-based management
Yes
Yes
Yes
Yes
• MIB support
Yes
Yes
Yes
Yes
• TRAPs via email
Yes
Yes
Yes
Yes
• Configuration with STEP 7
Yes
Yes
Yes
Yes
• RMON
Yes
Yes
Yes
Yes
• SMTP server
-
-
-
-
• Port mirroring
Yes
Yes
Yes
Yes
• CoS
Yes
Yes
Yes
Yes
• for IRT PROFINET IO switch
-
-
-
-
• PROFINET IO diagnosis
Yes
Yes
Yes
Yes
• switch-managed
Yes
Yes
Yes
Yes
Article No.
6GK5324-4GG00-3ER2
6GK5324-4GG00-3JR2
6GK5324-4GG00-4ER2
6GK5324-4GG00-4JR2
Product-type designation
SCALANCE XR324-4M EEC
SCALANCE XR324-4M EEC
SCALANCE XR324-4M EEC
SCALANCE XR324-4M EEC
© Siemens AG 2014