SIEMENS
2/271
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
Product functions
VLAN
Product function
• VLAN - port based
Yes
Yes
• VLAN dynamic
Yes
Yes
Number of VLANs maximum
255
255
Number of VLANs -
dynamic maximum
255
255
Protocol is supported GVRP
Yes
Yes
Product functions
DHCP
Product function
• DHCP client
Yes
Yes
• DHCP Option 82
Yes
Yes
• DHCP Option 66
Yes
Yes
• DHCP Option 67
Yes
Yes
Product functions
Redundancy
Product function
• Ring redundancy
Yes
Yes
• Redundancy manager
Yes
Yes
• Standby redundancy
Yes
Yes
• High Speed Redundancy Protocol
(HRP)
Yes
Yes
• Media Redundancy Protocol (MRP)
Yes
Yes
• redundancy procedure STP
Yes
Yes
• RSTP redundancy protocol
Yes
Yes
• redundancy procedure MSTP
Yes
Yes
• Passive listening
Yes
Yes
Protocol is supported
• STP/RSTP
Yes
Yes
• STP
Yes
Yes
• RSTP
Yes
Yes
• RSTP big network support
Yes
Yes
• LACP
Yes
Yes
Product functions
Security
Product function
• ACL - port/MAC-based
Yes
Yes
• IEEE 802.1x (radius)
Yes
Yes
• Broadcast/Multicast/Unicast Limiter
Yes
Yes
• broadcast blocking
Yes
Yes
Protocol is supported SSH
Yes
Yes
Product functions
Time
Product function SICLOCK support
Yes
Yes
Protocol is supported
• NTP
No
No
• SNTP
Yes
Yes
• MSTP
Yes
Yes
• IEEE 1588 profile default
Yes
Yes
Standards, specifications,
approvals
Standard
• for EMC from FM
FM3611: Class 1, Division 2, Group A, B, C, D / T4,
Class 1, Zone 2, Group IIC, T4
FM3611: Class 1, Division 2, Group A, B, C, D / T4,
Class 1, Zone 2, Group IIC, T4
• for hazardous zone
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4
KEMA 07 ATEX 0145X
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4
KEMA 07 ATEX 0145X
• for safety of CSA and UL
UL 60950-1, CSA C22.2 No. 60950-1
UL 60950-1, CSA C22.2 No. 60950-1
• for hazardous area of CSA and UL
UL 1604 and UL 2279-15 (Hazardous Location),
CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A,
B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4
UL 1604 and UL 2279-15 (Hazardous Location),
CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A,
B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4
• for emitted interference
EN 61000-6-4:2007 (Class A)
EN 61000-6-4
• for interference immunity
EN 61000-6-2:2005
EN 61000-6-2
Verification of suitability
EN 61000-6-2:2005, EN 61000-6-4:2007
EN 61000-6-2, EN 61000-6-4
• CE mark
Yes
Yes
• C-Tick
Yes
Yes
• KC approval
Yes
Yes
• Railway application in accordance
with EN 50155
No
Yes
Article No.
6GK5308-2GG00-2AA2
6GK5308-2GG00-2CA2
Product-type designation
SCALANCE X308-2M
SCALANCE X308-2M TS