SIEMENS
2/313
Siemens IK PI · 2015
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300EEC managed
2
■
Technical specifications
Article No.
6GK5302-7GD00-1EA3
6GK5302-7GD00-1GA3
6GK5302-7GD00-2EA3
6GK5302-7GD00-2GA3
Product-type designation
SCALANCE X302-7EEC
SCALANCE X302-7EEC
SCALANCE X302-7EEC
SCALANCE X302-7EEC
Transmission rate
Transfer rate 1
10 Mbit/s
10 Mbit/s
10 Mbit/s
10 Mbit/s
Transfer rate 2
100 Mbit/s
100 Mbit/s
100 Mbit/s
100 Mbit/s
Transfer rate 3
1 000 Mbit/s
1 000 Mbit/s
1 000 Mbit/s
1 000 Mbit/s
Interfaces
Number of electrical/optical
connections for network components
or terminal equipment maximum
9
9
9
9
Number of electrical connections
• for network components
and terminal equipment
2
2
2
2
• for operator console
-
-
-
-
• for signaling contact
1
1
2
2
• for media module
-
-
-
-
• for power supply
1
1
2
2
• for redundant power supply
1
1
2
2
Design of electrical connection
• for network components
and terminal equipment
RJ45 port
RJ45 port
RJ45 port
RJ45 port
• for signaling contact
2-pole terminal block
2-pole terminal block
2-pole terminal block
2-pole terminal block
• for power supply
4-pole terminal block
4-pole terminal block
2 x 4-pole terminal block
2 x 4-pole terminal block
Number of optical interfaces
for optical waveguide
• at 100 Mbit/s
7
7
7
7
Design of optical interface
for optical waveguide
• at 100 Mbit/s
LC port
(multimode up to 5 km)
LC port
(multimode up to 5 km)
LC port
(multimode up to 5 km)
LC port
(multimode up to 5 km)
Connectable optical power
relative to 1 mW
• of the transmitter output
-19 … -14 dB
-19 … -14 dB
-19 … -14 dB
-19 … -14 dB
• of the receiver input maximum
-14 dB
-14 dB
-14 dB
-14 dB
Optical sensitivity relative to 1 mW
of the receiver input minimum
-32 dB
-32 dB
-32 dB
-32 dB
Attenuation of fiber-optic cable
transmission link minimum necessary
0 dB
0 dB
0 dB
0 dB
Range at the optical interface
depending on the optical fiber used
0 … 5 km
0 … 5 km
0 … 5 km
0 … 5 km
Design of the removable storage
C-PLUG
Yes
Yes
Yes
Yes
Signal-Inputs/outputs
Operating voltage of signaling
contacts at DC rated value
24 V
24 V
24 V
24 V
Operating current of signaling
contacts at DC maximum
0.1 A
0.1 A
0.1 A
0.1 A
Supply voltage,
current consumption, power loss
Type of supply voltage redundant
power supply unit
No
No
Yes
Yes
Type of supply voltage
DC
DC
DC
DC
Type 2 of supply voltage
DC
DC
DC
DC
Supply voltage for DC
24 V
24 V
24 V
24 V
• rated value
19.2 … 57.6 V
19.2 … 57.6 V
19.2 … 57.6 V
19.2 … 57.6 V
Product component fusing
at power supply input
Yes
Yes
Yes
Yes
Type of fusing at input
for supply voltage
T 4 A / 125 V
T 4 A / 125 V
T 4 A / 125 V
T 4 A / 125 V
Consumed current maximum
0.75 A
0.75 A
0.75 A
0.75 A
Active power loss
• at 24 V for DC
17 W
17 W
17 W
17 W
© Siemens AG 2014