SIEMENS
2/304
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XR-300PoE managed
Product functions
Security
Product function
• ACL - port/MAC-based
Yes
Yes
Yes
• IEEE 802.1x (radius)
Yes
Yes
Yes
• Broadcast/Multicast/Unicast Limiter
Yes
Yes
Yes
• broadcast blocking
Yes
Yes
Yes
Protocol is supported SSH
Yes
Yes
Yes
Product functions
Time
Product function SICLOCK support
Yes
Yes
Yes
Protocol is supported
• NTP
Yes
Yes
Yes
• SNTP
Yes
Yes
Yes
• IEEE 1588 profile default
Yes
Yes
Yes
Standards, specifications,
approvals
Standard
• for EMC from FM
FM3611: Class 1, Division 2, Group A,
B, C, D / T4, Class 1, Zone 2,
Group IIC, T4
FM3611: Class 1, Division 2, Group A,
B, C, D / T4, Class 1, Zone 2,
Group IIC, T4
FM3611: Class 1, Division 2, Group A,
B, C, D / T4, Class 1, Zone 2,
Group IIC, T4
• for hazardous zone
EN 60079-0 : 2006,
EN 60079-15: 2005, II 3 G Ex nA II T4
KEMA 07 ATEX 0145X
EN 60079-0 : 2006,
EN 60079-15: 2005, II 3 G Ex nA II T4
KEMA 07 ATEX 0145X
EN 60079-0 : 2006,
EN 60079-15: 2005, II 3 G Ex nA II T4
KEMA 07 ATEX 0145X
• for safety of CSA and UL
UL 60950-1, CSA C22.2 No. 60950-1
UL 60950-1, CSA C22.2 No. 60950-1
UL 60950-1, CSA C22.2 No. 60950-1
• for hazardous area of CSA and UL
UL 1604 and UL 2279-15
(Hazardous Location), CSA C22.2 No.
213-M1987, Class 1 / Division 2 /
Group A, B, C, D / T4, Class 1 /
Zone 2 / Group IIC / T4
UL 1604 and UL 2279-15
(Hazardous Location), CSA C22.2 No.
213-M1987, Class 1 / Division 2 /
Group A, B, C, D / T4, Class 1 /
Zone 2 / Group IIC / T4
UL 1604 and UL 2279-15
(Hazardous Location), CSA C22.2 No.
213-M1987, Class 1 / Division 2 /
Group A, B, C, D / T4, Class 1 /
Zone 2 / Group IIC / T4
• for emitted interference
EN 61000-6-4:2007 (Class A)
EN 61000-6-4:2007 (Class A)
EN 61000-6-4:2007 (Class A)
• for interference immunity
EN 61000-6-2:2006
EN 61000-6-2:2006
EN 61000-6-2:2006
Verification of suitability
EN 61000-6-2:2006,
EN 61000-6-4:2007
EN 61000-6-2:2006,
EN 61000-6-4:2007
EN 61000-6-2:2006,
EN 61000-6-4:2007
Verification of suitability
• CE mark
Yes
Yes
Yes
• C-Tick
Yes
Yes
Yes
• KC approval
No
No
No
• Railway application in accordance
with EN 50155
-
-
Yes
Article No.
6GK5324-4QG00-3AR2
6GK5324-4QG00-3HR2
Product-type designation
SCALANCE XR324-4M POE
SCALANCE XR324-4M POE
Transmission rate
Transfer rate 1
10 Mbit/s
10 Mbit/s
Transfer rate 2
100 Mbit/s
100 Mbit/s
Transfer rate 3
1 000 Mbit/s
1 000 Mbit/s
Interfaces
Number of electrical/optical connec-
tions for network components or ter-
minal equipment maximum
24
24
Number of electrical connections
• for network components and termi-
nal equipment
16
16
• for Power-over-Ethernet for network
components or terminal equipment
8
8
• for operator console
1
1
• for signaling contact
1
1
• for media module
4
4
• for power supply
1
1
• for redundant power supply
0
0
Article No.
6GK5324-4QG00-1AR2
6GK5324-4QG00-1HR2
6GK5324-4QG00-1CR2
Product-type designation
SCALANCE XR324-4M POE
SCALANCE XR324-4M POE
SCALANCE XR324-4M POE TS