SIEMENS
2/269
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-300 managed
Article No.
6GK5308-2GG00-2AA2
6GK5308-2GG00-2CA2
Product-type designation
SCALANCE X308-2M
SCALANCE X308-2M TS
Transmission rate
Transfer rate 1
10 Mbit/s
10 Mbit/s
Transfer rate 2
100 Mbit/s
100 Mbit/s
Transfer rate 3
1 000 Mbit/s
1 000 Mbit/s
Interfaces
Number of electrical/optical
connections for network components
or terminal equipment maximum
8
8
Number of electrical connections
• for network components
and terminal equipment
4
4
• for signaling contact
1
1
• for media module
2
2
• for power supply
1
1
• for redundant power supply
1
1
Design of electrical connection
• for network components
and terminal equipment
RJ45 port
RJ45 port
• for signaling contact
2-pole terminal block
2-pole terminal block
• for power supply
4-pole terminal block
4-pole terminal block
Design of optical interface
for optical waveguide
• at 100 Mbit/s
Dependent on selected media modules
Dependent on selected media modules
• at 1 000 Mbit/s
Dependent on selected media modules
Dependent on selected media modules
Design of the removable storage
C-PLUG
Yes
Yes
Signal-Inputs/outputs
Operating voltage of signaling
contacts at DC rated value
24 V
24 V
Operating current of signaling
contacts at DC maximum
0.1 A
0.1 A
Supply voltage,
current consumption, power loss
Type of supply voltage redundant
power supply unit
No
No
Type of supply voltage
DC
DC
Supply voltage external
24 V
12 V
• minimum
18 V
20 V
• maximum
32 V
30 V
Product component fusing
at power supply input
Yes
Yes
Type of fusing at input for supply volt-
age
F 3 A / 32 V
F 3 A / 32 V
Consumed current maximum
0.7 A
0.7 A
Active power loss
• at 24 V for DC
16.6 W
16.6 W
Permitted ambient conditions
Ambient temperature
• during operating
-40 … +70 °C
-40 … +70 °C
• during storage
-40 … +70 °C
-40 … +70 °C
• during transport
-40 … +70 °C
-40 … +70 °C
• Comment
Reduced operating temperature through the use of
media modules (-40 °C to +70 °C) or
SFP plug-in transceivers (-40 °C to +60 °C).
If the device is installed in the vertical position,
the maximum operating temperature is reduced to +50 °C.
Reduced operating temperature through the use of
media modules (-40 °C to +70 °C) or
SFP plug-in transceivers (-40 °C to +60 °C).
If the device is installed in the vertical position,
the maximum operating temperature is reduced to +50 °C.
Relative humidity at 25 °C without
condensation during operating
maximum
95 %
95 %
Ambient condition for (standard)
operation mode
-
Conformal coating, no
Protection class IP
IP20
IP20
© Siemens AG 2014