SIEMENS
2/508
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC RTX F
• Address area
-
Inputs, max.
16 kbyte
-
Outputs, max.
16 kbyte
-
User data per address area, max.
2 kbyte
-
User data consistency, max.
254 byte
SIMATIC communication
• PG/OP communication
Yes
• S7 routing
Yes
• S7 communication
Yes
• Number of connections, max.
32
Open IE communication
• Open IE communication, supported
Yes
• Number of connections, max.
32
• Local port numbers used at the
system end
0, 20, 21, 25, 80, 102, 135, 161,
34962, 34963, 34964, 65532, 65533,
65534, 65535
Isochronous mode
Isochronous operation (application
synchronized up to terminal)
Yes
Number of DP masters with
isochronous mode
2
User data per isochronous slave,
max.
128 byte
Equidistance
Yes
Shortest clock pulse
2.2 ms;
2.2 ms without partial process image;
2.2 ms with partial process image
Communication functions
PG/OP communication
Yes
Data record routing
Yes; Only with CP 5611 or integrated
PROFIBUS interface of the
SIMATIC PC
Global data communication
• supported
No
S7 basic communication
• supported
No
S7 communication
• supported
Yes
• as server
Yes
• As client
Yes
• User data per job, max.
64 kbyte;
Depends on which block is used:
BSEND/USEND or PUT/GET
Open IE communication
• TCP/IP
Yes
-
Number of connections, max.
32
-
Data length for connection type
01H, max.
Not supported
-
Data length for connection type
11H, max.
65 534 byte
-
Data length, max.
65 534 byte
• ISO-on-TCP (RFC1006)
Yes
-
Number of connections, max.
32
-
Data length, max.
65 534 byte
• UDP
Yes
-
Number of connections, max.
32
-
Data length, max.
1 472 byte
Web server
• Supported
Yes
• Number of HTTP clients
2
• User-defined websites
No
6ES7671-1RC08-0YA0
SIMATIC WinAC RTX F 2010
PROFINET CBA
(at set setpoint communication load)
• Setpoint for the CPU
communication load
20 %
• Number of remote interconnection
partners
64
• Number of functions, master/slave
30
• Total of all Master/Slave
connections
1 000
• Data length of all incoming
connections master/slave, max.
6 800 byte
• Data length of all outgoing
connections master/slave, max.
6 800 byte
• Number of device-internal and
PROFIBUS interconnections
500
• Data length of device-internal and
PROFIBUS interconnections, max.
4 000 byte
• Data length per connection, max.
1 400 byte
• Remote interconnections
with acyclic transmission
-
Sampling frequency:
Sampling time, min.
500 ms
-
Number of incoming
interconnections
100
-
Number of outgoing
interconnections
100
-
Data length of all incoming
-
interconnections, max.
2 000 byte
-
Data length of all outgoing
-
interconnections, max.
2 000 byte
-
Data length per connection, max.
1 400 byte
• Remote interconnections with cyclic
transmission
-
Transmission frequency:
Transmission interval, min.
10 ms
-
Number of incoming
interconnections
200
-
Number of outgoing
interconnections
200
-
Data length of all incoming
interconnections, max.
4 800 byte
-
Data length of all outgoing
interconnections, max.
4 800 byte
-
Data length per connection, max.
250 byte
• HMI variables via PROFINET
(acyclic)
-
Number of stations that can log on
for HMI variables (PN OPC/iMap)
3
-
HMI variable updating
500 ms
-
Number of HMI variables
200
-
Data length of all HMI variables,
max.
2 000 byte
• PROFIBUS proxy functionality
- supported
Yes
-
Number of linked PROFIBUS
devices
16
-
Data length per connection, max.
240 byte; Slave-dependent
Number of connections
• overall
96
• usable for PG communication
-
reserved for PG communication
1
• usable for OP communication
-
reserved for OP communication
1
6ES7671-1RC08-0YA0
SIMATIC WinAC RTX F 2010
© Siemens AG 2014