SIEMENS
2/502
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC RTX
• Remote interconnections
with cyclic transmission
-
Transmission frequency:
Transmission interval, min.
10 ms
-
Number of incoming
interconnections
200
-
Number of outgoing
interconnections
200
-
Data length of all incoming
interconnections, max.
4 800 byte
-
Data length of all outgoing
interconnections, max.
4 800 byte
-
Data length per connection, max.
250 byte
• HMI variables via PROFINET
(acyclic)
-
Number of stations that can log on
for HMI variables (PN OPC/iMap)
3
-
HMI variable updating
500 ms
-
Number of HMI variables
200
-
Data length of all HMI variables,
max.
2 000 byte
• PROFIBUS proxy functionality
- supported
Yes
-
Number of linked PROFIBUS
devices
16
-
Data length per connection, max.
240 byte; Slave-dependent
Number of connections
• overall
96
• usable for PG communication
-
reserved for PG communication
1
• usable for OP communication
-
reserved for OP communication
1
S7 message functions
Number of login stations for
message functions, max.
62
SCAN procedure
No
Process diagnostic messages
Yes; ALARM_S, ALARM_SQ,
ALARM_D, ALARM_DQ
simultaneously active
Alarm-S blocks, max.
20; of a total of 20 for all SFCs
Alarm 8-blocks
Yes
• Number of instances for alarm 8
and S7 communication blocks, max.
4 000
Process control messages
No
Number of archives that can log on
simultaneously (SFB 37 AR_SEND)
32
Test commissioning functions
Status block
Yes
Single step
Yes
Number of breakpoints
20
Status/control
• Status/control variable
Yes
Forcing
• Forcing
No
Diagnostic buffer
• present
Yes
• Number of entries, max.
- adjustable
Yes
- preset
120
Hardware requirements
Hardware required
PC with color monitor, keyboard,
mouse or pointing device for Windows
Main memory, min.
1 Gbyte; WES7: 2 GB
Required memory on hard disk, min.
100 Mbyte
Processor
Intel Celeron M,
900 MHz or compatible
• Multi-processor system
Yes; Dual Pentium, CoreDuo,
Core2Duo or compatible
• Hyper-threading
Yes
6ES7671-0RC08-0YA0
SIMATIC WinAC RTX 2010
Operating systems
Windows CE
No
Windows NT 4.0
No
Windows 2000
No
Windows XP
Yes; Professional, SP2 and SP3
Windows XP embedded
Yes; With the delivery image of the
SIMATIC PC
• Supported HAL types under
Windows XP
ACPI uniprocessor PC,
ACPI multiprocessor PC,
MPS multiprocessor PC
Windows Vista
No
Windows 7
Yes; Professional, Enterprise,
Ultimate (only 32 bits)
Windows embedded Standard 7
Yes; With the delivery image of the
SIMATIC PC
Configuration
Configuration software
• STEP 7
Yes; V5.5 and higher, Engineering
Tools (optional)
programming
• Nesting levels
8
• Programming language
- LAD
Yes
- FBD
Yes
- STL
Yes
- SCL
Yes
- CFC
Yes
- GRAPH
Yes
- HiGraph®
Yes
• Software libraries
-
Easy Motion Control
Yes
-
Software redundancy
Yes; As of V1.2, only operation of
WinAC RTX with WinAC RTX
• Number of simultaneously active
SFCs
- DPSYC_FR
20; of a total of 20 for all SFCs
- D_ACT_DP
20; of a total of 20 for all SFCs
- RD_REC
20; of a total of 20 for all SFCs
- WR_REC
20; of a total of 20 for all SFCs
- WR_PARM
20; of a total of 20 for all SFCs
- PARM_MOD
20; of a total of 20 for all SFCs
- WR_DPARM
20; of a total of 20 for all SFCs
- DPNRM_DG
20; of a total of 20 for all SFCs
- RDSYSST
20; of a total of 20 for all SFCs
• Number of simultaneously active
SFBs
- RD_REC
20; of a total of 20 for all SFBs
- WR_REC
20; of a total of 20 for all SFBs
Know-how protection
• User program protection/password
protection
Yes
• Block encryption
No
Open Development interfaces
• CCX (Custom Code Extension)
Yes; WinAC ODK V4.2 or higher
• CMI (Controller Management Inter-
face)
Yes; WinAC ODK V4.2 or higher
• SMX (Shared Memory Extension)
Yes; WinAC ODK V4.2 or higher
- Inputs
4 kbyte
- Outputs
4 kbyte
I/O/Options
I/O devices
none
• Printer
No
Weights
Weight, approx.
100 g; Weight incl. packaging
6ES7671-0RC08-0YA0
SIMATIC WinAC RTX 2010
© Siemens AG 2014