SIEMENS
2/499
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Controllers / PC-based controllers
SIMATIC WinAC RTX
Data areas and their retentivity
Retentivity without UPS
and PS Extension Board
128 KB with SIMATIC IPC227D,
IPC427C, IPC427D, HMI IPC277D,
IPC477C, IPC477D;
further SIMATIC IPCs on request
Retentivity with UPS
all data
Flag
• Number, max.
16 kbyte
• of which retentive
MB 0 to MB 16383
• Retentivity preset
MB 0 to MB 15
• Number of clock memories
8
Data blocks
• Number, max.
Limited only by available retentive
memory (NVRAM, or file storage)
• Size, max.
64 kbyte
• Retentivity adjustable
Yes; via non-retain property on DB
• Retentivity preset
Yes
Local data
• adjustable, max.
64 kbyte
• preset
32 kbyte
• per priority class, max.
61 440 byte
Address area
I/O address area
• Inputs
16 kbyte
• Outputs
16 kbyte
• of which, distributed
-
DP interface, inputs
16 kbyte
-
DP interface, outputs
16 kbyte
-
PN interface, inputs
16 kbyte
-
PN interface, outputs
16 kbyte
Process image
• Inputs, adjustable
8 kbyte;
16 KB with STEP 7 V5.5 SP3 or higher
• Outputs, adjustable
8 kbyte;
16 KB with STEP 7 V5.5 SP3 or higher
• Inputs, default
512 byte
• Outputs, default
512 byte
Subprocess images
• Number of subprocess images,
max.
15
Digital channels
• Inputs
128 000
• Outputs
128 000
Analog channels
• Inputs
8 000
• Outputs
8 000
Hardware configuration
Submodules
• Number of submodules, max
4
• of which PROFIBUS, max.
4;
Supported interfaces: see 1st and
2nd interface
• of which Industrial Ethernet, max.
1;
Supported interfaces: see 3rd and
4th interface
Number of operable FMs and CPs
(recommended)
• FM
FM distributed: FM 350-1 / 350-2,
FM 351, FM 352, FM 353,
FM 355 / 355-2
• CP, point-to-point
CP 340, CP 341 distributed
• CP, LAN
Over PC CP
6ES7671-0RC08-0YA0
SIMATIC WinAC RTX 2010
Time of day
Clock
• Hardware clock (real-time clock)
Yes
• battery-backed and synchronizable
Yes
Operating hours counter
• Number
8
Clock synchronization
• supported
Yes
• to PC-CP, slave
Yes
• on Ethernet via NTP
Yes
Interfaces
Number of USB interfaces
0
1st interface
Interface type
CP 5611, CP 5611-A2, CP 5612,
CP 5621, CP 5622,
integrated PROFIBUS interface
of the SIMATIC PC
Max. no. of simultaneously
operable CPs
1
Physics
RS 485 / PROFIBUS
Isolated
Yes
Power supply to interface
(15 to 30 V DC), max.
does not exist
Number of connection resources
8
Functionality
• MPI
No
• DP master
Yes
• DP slave
No
DP master
• Number of connections, max.
8
• Transmission rate, max.
12 Mbit/s
• Number of DP slaves, max.
64
• Services
-
PG/OP communication
Yes
- Routing
Yes
-
Global data communication
No
-
S7 basic communication
No
-
S7 communication
Yes
-
S7 communication, as client
Yes
-
S7 communication, as server
Yes
-
Equidistance mode support
Yes; Only in conjunction
with isochronous mode
-
Isochronous mode
Yes
- SYNC/FREEZE
Yes
-
Activation/deactivation of DP
slaves
Yes
-
Direct data exchange
(slave-to-slave communication)
Yes
- DPV0
Yes
- DPV1
Yes
• Address area
-
Inputs, max.
16 kbyte
-
Outputs, max.
16 kbyte
• User data per DP slave
-
Inputs, max.
244 byte
-
Outputs, max.
244 byte
6ES7671-0RC08-0YA0
SIMATIC WinAC RTX 2010
© Siemens AG 2014