SIEMENS
2/417
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
Article No.
6GK5991-1AD00-8AA0
6GK5991-1AF00-8AA0
6GK5991-1AE00-8AA0
6GK5991-1AE30-8AA0
Product-type designation
SFP991-1
SFP991-1LD
SFP991-1LH+
SFP991-1ELH200
Interfaces
Number of electrical/optical
connections for network components
or terminal equipment maximum
1
1
1
1
Number of 10/100/1 000 Mbit/s
M12 ports
-
-
-
-
Number of 10/100/1 000 Mbit/s
RJ45 ports
-
-
-
-
Number of electrical connections
• for Power-over-Ethernet for network
components or terminal equipment
-
-
-
-
• for SFP+/SFP
-
-
-
-
Design of electrical connection
• for network components
and terminal equipment
-
-
-
-
• for Power-over-Ethernet for network
components or terminal equipment
-
-
-
-
Number of 100 Mbit/s
ST(BFOC) ports
-
-
-
-
Number of 100 Mbit/s SC ports
-
-
-
-
Number of 100 Mbit/s LC ports
1
1
1
1
Number of 1 000 Mbit/s LC ports (LX)
-
-
-
-
Number of 1 000 Mbit/s LC ports (SX)
-
-
-
-
Number of 1 000 Mbit/s SC ports (LX)
-
-
-
-
Number of 1 000 Mbit/s SC ports (SX)
-
-
-
-
Number of 10 Gbit/s LC ports (LX)
-
-
-
-
Number of 10 Gbit/s LC ports (SX)
-
-
-
-
Design of optical connections
for network components or terminal
devices
LC
LC
LC
LC
Connectable optical power relative
to 1 mW
• of the transmitter output
-19 … -14 dB
-15 … -8 dB
-5 … +0 dB
1 … 5 dB
• of the receiver input maximum
-3 dB
-3 dB
-3 dB
-9 dB
Optical sensitivity relative to 1 mW
of the receiver input minimum
-32 dB
-34 dB
-34 dB
-42 dB
Attenuation of fiber-optic cable
transmission link minimum necessary
0 dB
0 dB
3 dB
14 dB
Range at the optical interface
depending on the optical fiber used
0 … 5 km
0 … 26 km
12 … 70 km
61 … 200 km
Permitted ambient conditions
Ambient temperature
• during operating
-40 … +85 °C
-40 … +85 °C
-40 … +85 °C
-40 … +85 °C
• during storage
-40 … +85 °C
-40 … +85 °C
-40 … +85 °C
-40 … +85 °C
• during transport
-40 … +85 °C
-40 … +85 °C
-40 … +85 °C
-40 … +85 °C
Relative humidity at 25 °C without
condensation during operating
maximum
95 %
95 %
95 %
95 %
Ambient condition for (standard)
operation mode
-
-
-
-
Protection class IP
IP20
IP20
IP20
IP20
© Siemens AG 2014