SIEMENS
2/415
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
Media modules for modular SCALANCE XR-500 managed
Verification of suitability
EN 61000-6-2, EN 61000-6-4
EN 61000-6-2, EN 61000-6-4
• CE mark
Yes
Yes
• C-Tick
Yes
Yes
• KC approval
Yes
Yes
• Railway application in accordance
with EN 50155
-
-
• Railway application in accordance
with EN 50124-1
-
-
• IEC 61850-3
-
-
Marine classification association
• American Bureau
of Shipping Europe Ltd. (ABS)
-
-
• Bureau Veritas (BV)
-
-
• Det Norske Veritas (DNV)
-
-
• Germanische Lloyd (GL)
-
-
• Lloyds Register of Shipping (LRS)
-
-
• Nippon Kaiji Kyokai (NK)
-
-
Article No.
6GK5991-4AB00-8AA0
6GK5991-4AC00-8AA0
Product-type designation
MM991-4
MM991-4LD
Article No.
6GK5992-4AL00-8AA0
6GK5992-4AM00-8AA0
6GK5992-4AS00-8AA0
Product-type designation
MM992-4
MM992-4LD
MM992-4SFP
Interfaces
Number of electrical/optical
connections for network components
or terminal equipment maximum
4
4
4
Number of 10/100/1 000 Mbit/s
M12 ports
-
-
-
Number of 10/100/1 000 Mbit/s
RJ45 ports
-
-
-
Number of electrical connections
• for Power-over-Ethernet for network
components or terminal equipment
-
-
-
• for SFP+/SFP
-
-
4
Design of electrical connection
• for network components
and terminal equipment
-
-
-
• for Power-over-Ethernet for network
components or terminal equipment
-
-
-
Number of 100 Mbit/s
ST(BFOC) ports
-
-
-
Number of 100 Mbit/s SC ports
-
-
-
Number of 100 Mbit/s LC ports
-
-
-
Number of 1 000 Mbit/s LC ports (LX)
-
-
-
Number of 1 000 Mbit/s LC ports (SX)
-
-
-
Number of 1 000 Mbit/s SC ports (LX)
-
4
-
Number of 1 000 Mbit/s SC ports (SX)
4
-
-
Number of 10 Gbit/s LC ports (LX)
-
-
-
Number of 10 Gbit/s LC ports (SX)
-
-
-
Design of optical connections
for network components or terminal
devices
SC
SC
-
Connectable optical power relative
to 1 mW
• of the transmitter output
-9.5 ... -4 dB
-9.5 ... -3 dB
- -
• of the receiver input maximum
-3 dB
-3 dB
-
Optical sensitivity relative to 1 mW of
the receiver input minimum
-17 dB
-21 dB
-
Attenuation of fiber-optic cable
transmission link minimum necessary
0 dB
0 dB
-
Range at the optical interface
depending on the optical fiber used
0 ... 0.75 km
0 ... 10 km
- -
© Siemens AG 2014