SIEMENS
2/401
Siemens IK PI · 2015
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XR-500 managed
2
■
Technical specifications
Article No.
6GK5552-0AA00-2AR2
6GK5552-0AR00-2AR2
6GK5528-0AA00-2AR2
6GK5528-0AR00-2AR2
6GK5552-0AA00-2HR2
6GK5552-0AR00-2HR2
6GK5528-0AA00-2HR2
6GK5528-0AR00-2HR2
Product-type designation
SCALANCE XR552-12M
SCALANCE XR552-12M
SCALANCE XR528-6M
SCALANCE XR528-6M
Transmission rate
Transfer rate 1
10 Mbit/s
10 Mbit/s
10 Mbit/s
10 Mbit/s
Transfer rate 2
100 Mbit/s
100 Mbit/s
100 Mbit/s
100 Mbit/s
Transfer rate 3
1 000 Mbit/s
1 000 Mbit/s
1 000 Mbit/s
1 000 Mbit/s
Transfer rate 4
10 Gbit/s
10 Gbit/s
10 Gbit/s
10 Gbit/s
Interfaces
Number of electrical/optical
connections for network components
or terminal equipment maximum
52
52
28
28
Number of electrical connections
• for SFP+/SFP
4
4
4
4
• for operator console
1
1
1
1
• for management purposes
1
1
1
1
• for signaling contact
1
1
1
1
• for media module
12
12
6
6
• for power supply
1
1
1
1
• for redundant power supply
1
1
1
1
Design of electrical connection
• for network components
and terminal equipment
Dependent on selected
media modules
Dependent on selected
media modules
Dependent on selected
media modules
Dependent on selected
media modules
• for Power-over-Ethernet for network
components or terminal equipment
RJ45 port
RJ45 port
RJ45 port
RJ45 port
• for operator console
RJ11 port
RJ11 port
RJ11 port
RJ11 port
• for management purposes
RJ45 port
RJ45 port
RJ45 port
RJ45 port
• for signaling contact
2-pole terminal block
2-pole terminal block
2-pole terminal block
2-pole terminal block
• for power supply
4-pole terminal block
4-pole terminal block
4-pole terminal block
4-pole terminal block
Design of optical interface
for optical waveguide
• at 100 Mbit/s
Dependent on selected
media modules
Dependent on selected
media modules
Dependent on selected
media modules
Dependent on selected
media modules
• at 1 000 Mbit/s
Dependent on selected
media modules
Dependent on selected
media modules
Dependent on selected
media modules
Dependent on selected
media modules
Design of the removable storage
C-PLUG/KEY-PLUG
Yes
Yes
Yes
Yes
Signal-Inputs/outputs
Operating voltage of signaling
contacts at DC rated value
24 V
24 V
24 V
24 V
Operating current of signaling
contacts at DC maximum
0.1 A
0.1 A
0.1 A
0.1 A
Supply voltage,
current consumption, power loss
Type of supply voltage
DC
DC
DC
DC
Supply voltage external
24 V
24 V
24 V
24 V
• minimum
19.2 V
19.2 V
19.2 V
19.2 V
• maximum
28.8 V
28.8 V
28.8 V
28.8 V
Product component fusing
at power supply input
Yes
Yes
Yes
Yes
Type of fusing at input
for supply voltage
F 15 A / 125 V
F 15 A / 125 V
F 15 A / 125 V
F 15 A / 125 V
© Siemens AG 2014