SIEMENS
2/382
Siemens IK PI · 2015
2
■
Function
(continued)
PROFINET/Industrial Ethernet
Industrial Ethernet Layer 3 Switches / Routers
SCALANCE XM-400 managed
Network management
The network management provides the following functions:
•
Password-protected dial-up for "Administrator" (read and write
authorization) and "User" (read only)
•
Access protection by means of access control list
•
Encrypted HTTPS access
•
Read-out of version and status information
•
Setting the signal and standby mask and address information
•
Fixed parameterization of the ports (data rates, half/full
duplex)
•
Setting parameters of the VLANs and multicast services
•
Parameterization of the standby connections for a redundant
ring link
•
Setting of Rapid Spanning Tree parameters
•
Defining a maximum load per port for load limiting
(port thresholds)
•
Output of statistics information
•
Diagnosis of data traffic by means of a parameterizable mirror
port with a standard commercial network analyzer
•
Loading of new firmware or the configuration data via the
network by a TFTP server
•
Saving the configuration data or log table via the network on a
TFTP server
•
Configuration of the IP routing function after activation with
KEY-PLUG (static routing, dynamic routing (OSPF, RIP v1/2),
and redundant routing (VRRP))
If faults occur in the network, the SCALANCE XM-400 switch
can independently send error messages (traps) to a network
management system (e.g. SINEMA Server) or also e-mails to a
predefined network administrator.
Remote monitoring (RMON) provides the following functions:
The SCALANCE XM-400 switch can collect statistics information
according to the RMON groups 1 through 4. These include,
for example, fault statistics that are kept for each port. This infor-
mation can be read out through Web-based management in the
statistics sub-area.
© Siemens AG 2014