SIEMENS
2/113
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Cabling technology
Glass fiber-optic cables
Permitted ambient conditions
Ambient temperature
• during operating
-40 … +85 °C
-20 … +60 °C
• during storage
-40 … +85 °C
-25 … +70 °C
• during transport
-40 … +85 °C
-25 … +70 °C
• during installation
-5 … +50 °C
-5 … +50 °C
Burning behaviour
Flame-retardant in accordance with IEC 60332-1-2
and IEC 60332-3-22 (Cat. A)
Flame-retardant in accordance with IEC 60332-1-2
and IEC 60332-3-22 (Cat. A)
Chemical resistance
• to mineral oil
not resistant
not resistant
• to grease
not resistant
not resistant
• to water
Conditional resistance
Conditional resistance
Radiological resistance
to UV radiation
resistant
not resistant
Product properties, functions,
components
general
Product feature
• halogen-free
No
Yes
• silicon-free
Yes
Yes
Product component
Rodent protection
No
No
Cable length for glass FOC
• for 100BaseFX
for Industrial Ethernet maximum
4 000 m
4 000 m
• for 1000BaseSX
for Industrial Ethernet maximum
350 m
350 m
• for 1000BaseLX
for Industrial Ethernet maximum
550 m
550 m
• for PROFIBUS maximum
3 000 m
3 000 m
Standards, specifications,
approvals
Verification of suitability
• RoHS conformity
Yes
Yes
Article No.
6XV1820-5AH10
6XV1820-7AH10
Product-type designation
Fiber optic standard cable
INDOOR fiber optic indoor cable
© Siemens AG 2014