SIEMENS
2/80
Siemens IK PI · 2015
PROFINET/Industrial Ethernet
Cabling technology
IE TP Cord
2
■
Technical specifications
Article No.
6XV1870-3QH10
6XV1850-2JH10
Product-type designation
IE TP Cord RJ45/RJ45, 4x2
IE TP Cord 9/RJ45, 2x2
Product description
Patch cable, preferred length, preassembled
with two RJ45 connectors
Patch cable, preferred length, preassembled
with one 9-pole Sub-D connector an one RJ45 connector
Acceptability for application
Easy connection of data terminals to the IE FC
cabling system
Easy connection of data terminals to the IE FC
cabling system
Cable designation
LI 02YSCH 4x2x0,15 PIMF GN FRNC
LI 02YSCY 2x2x0,15/0,98 PIMF ICCS GN
Cable length
1 m
1 m
Electrical data
Damping ratio per length
• at 10 MHz maximum
86 dB/km
85 dB/km
• at 100 MHz maximum
28 dB/km
278 dB/km
• at 300 MHz maximum
501 dB/km
5 dB/km
• at 600 MHz maximum
735 dB/km
733 dB/km
Impedance
• for frequency range
1 MHz … 100 MHz
100
100
• for frequency range
10 MHz … 600 MHz
100
100
Relative symmetrical tolerance
• of the surge impedance at
1 MHz … 100 MHz
15 %
15 %
• of the surge impedance at
10 MHz … 600 MHz
10 %
6 %
Transfer impedance at 10 MHz
10 m
/m
10 m
/m
Loop resistance per length maximum
290
/km
300
/km
Insulation resistance coefficient
500 G
·m
500 G
·m
Mechanical data
Number of electrical wires
8
4
Design of shield
Overlapped aluminum-clad foil, sheathed in a braided
screen of tin-plated copper wires
Overlapped aluminum-clad foil, sheathed in a braided
screen of tin-plated copper wires
AWG number
-
-
Core diameter
• of AWG26 core
0.5 mm
0.48 m
Outer diameter
• of the inner conductor
0.5 mm
0.48 mm
• of the wire insulation
1 mm
0.98 mm
• of the cable sheath
6.2 mm
-
Symmetrical tolerance
of outer diameter of cable sheath
0.3 mm
-
Width of the cable sheath
-
5.8 mm
Symmetrical tolerance
of width of cable sheath
-
0.2 mm
Thickness of the cable sheath
-
3.7 mm
Symmetrical tolerance
of thickness of cable sheath
-
0.2 mm