SIEMENS
2/79
Siemens IK PI · 2015
PROFINET/Industrial Ethernet
Cabling technology
IE TP Cord
2
■
Design
•
2 x 2 cores for 10/100 Mbit/s transmission rate;
4 x 2 cores for 10/100/1 000 Mbit/s transmission rate
•
Two cores with two dummy elements twisted into a pair.
•
Each pair is encased in plastic film and shielded with a
plastic-clad aluminum foil
•
Outer woven shield around all pairs comprising tinned copper
wires
•
Plastic sheath (PVC)
IE TP Cord is available as TP Cord 4 x 2, pre-assembled cables
in the following versions:
•
IE TP Cord RJ45/RJ45
with 2 x RJ45 plugs
•
IE TP XP Cord RJ45/RJ45
with 2 x RJ45 plugs, send and receive cables are twisted.
IE TP Cord is available as TP Cord 2 x 2, pre-assembled cables
in the following versions:
•
IE TP Cord 9/RJ45
with one 9-pole Sub-D connector and one RJ45 connector
•
IE TP XP Cord 9/RJ45
with one RJ45 connector and one 9-pole Sub-D connector,
send and receive cable are twisted
•
IE TP Cord 9-45/RJ45
with one RJ45 connector and one 9-pole Sub-D connector,
45° cable outlet
•
IE TP XP Cord 9-45/RJ45
with one RJ45 connector and one 9-pole Sub-D connector,
45° cable outlet; send and receive cable are twisted
•
IE TP XP Cord 9/9
with two 9-pole Sub-D connectors, send and receive cable
are twisted.
•
IE TP Cord RJ45/15
with one RJ45 connector and one 15-pole Sub-D connector;
this is used to directly connect data terminals with ITP inter-
faces to network components with an RJ45 interface.
•
IE TP XP Cord RJ45/15
with one RJ45 connector and one 15-pole Sub-D connector,
twisted send and receive cable; used for direct connection of
a data terminal with 15-pole Sub-D connector to a data
terminal with RJ45 plug.
•
IE TP Converter Cord 15/RJ45
with a 15-pole Sub-D socket with slide locking and an
RJ45 plug. A retaining clip clamps it in place.
IE TP Converter Cord 15/RJ45 2 x 2 is used to connect data
terminals with an RJ45 interface to the ITP cabling system,
e.g. over the ITP Standard 9/15 cable.
■
Function
The flexibility of the cable ensures easy installation, for example
in a control cabinet, or to connect equipment in a control room.
The maximum length of an IE TP Cord is 10 m.
Adapter cables are used to connect devices with a 9-pin ITP
interface to devices with an RJ45 interface.
The IE TP Converter Cord 15/RJ45 is used to connect devices
with a 15-pin ITP interface to devices with an RJ45 interface.
© Siemens AG 2014