SIEMENS
2/68
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 4 x 2
Permitted ambient conditions
Ambient temperature
• during operating
-40 … +80 °C
-40 … +85 °C
• during storage
-40 … +80 °C
-40 … +85 °C
• during transport
-40 … +80 °C
-40 … +85 °C
• during installation
-40 … +80 °C
-40 … +80 °C
Burning behaviour
flame resistant according to IEC 60332-1
flame resistant according to IEC 60332-3-24 (Category C)
Chemical resistance
• to mineral oil
oil resistant according to IEC 60811-2-1 (4 h / 70°C)
oil resistant according to IEC 60811-2-1 (4 h / 70°C)
• to grease
Conditional resistance
Conditional resistance
• to water
Conditional resistance
Conditional resistance
Radiological resistance to
UV radiation
Resistant
Resistant
Product properties, functions,
components
general
Product feature
• halogen-free
No
No
• silicon-free
Yes
Yes
Cable length
• with 100BaseTX
for Industrial Ethernet
90 m
100 m
• with 1000BaseT
for Industrial Ethernet
90 m
100 m
Standards, specifications,
approvals
UL/ETL listing with 300 V rating
Yes: c(UL)us, CMG, Sun Res
Yes: c(UL)us, CMG
UL/ETL style with 600 V rating
No
No
Verification of suitability
• CE mark
Yes
Yes
• RoHS conformity
Yes
Yes
Standard for structured cabling
Cat6
Cat6
Article No.
6XV1870-2E
6XV1878-2A
Product-type designation
IE FC TP Standard Cable GP 4x2 (AWG 22)
IE FC TP Standard Cable GP 4x2 (AWG 24)
© Siemens AG 2014