SIEMENS
2/62
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 2 x 2
Permitted ambient conditions
Ambient temperature
• during operating
-40 … +70 °C
-40 … +80 °C
• during storage
-40 … +70 °C
-40 … +80 °C
• during transport
-40 … +70 °C
-40 … +80 °C
• during installation
-5 … +50 °C
-20 … +60 °C
Ambient condition for (standard)
operation mode
-
Electrical characteristics measured at 20 ºC,
tests according to EN 50288-2-1
Burning behaviour
inflammable
BS6853, DIN5510-2 levels of protection 1-4,
prEN45545-2 Hazard Level HL1-HL3,
EN50306-4, NF F 16-101, NFPA130
Chemical resistance
• to mineral oil
Conditional resistance
EN 50306-4 (72h/100 °C, IRM 902, 168h/70 °C, IRM 903)
• to grease
Conditional resistance
Conditional resistance
• to water
Resistant
Conditional resistance
Radiological resistance
to UV radiation
Resistant
Resistant
Product properties, functions,
components
general
Product feature
• halogen-free
No
Yes
• silicon-free
Yes
Yes
Cable length with 100BaseTX for
Industrial Ethernet
100 m
100 m
Standards, specifications,
approvals
UL/ETL listing with 300 V rating
No
No
UL/ETL style with 600 V rating
No
No
Verification of suitability
• CE mark
Yes
Yes
• UL-registration
-
-
• RoHS conformity
Yes
Yes
Standard for structured cabling
Cat5e
Cat5
Marine classification association
• American Bureau
of Shipping Europe Ltd. (ABS)
No
No
• Bureau Veritas (BV)
No
No
• Det Norske Veritas (DNV)
No
No
• Germanische Lloyd (GL)
No
No
• Lloyds Register of Shipping (LRS)
No
No
Article No.
6XV1871-2G
6XV1871-2T
Product-type designation
IE TP Ground Cable 2x2 (Typ C)
IE TP Train Cable 2x2 (Typ C, AWG22/7)
© Siemens AG 2014