SIEMENS
2/61
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 2 x 2
Article No.
6XV1871-2G
6XV1871-2T
Product-type designation
IE TP Ground Cable 2x2 (Typ C)
IE TP Train Cable 2x2 (Typ C, AWG22/7)
Product description
Standard bus cable (4-core), for laying in soil,
sold by the meter, not assembled
Flexible bus cable with tin-coated stranded wires, (4-core)
for applications in trains, sold by the meter, not assembled
Acceptability for application
Standard cable with rigid cores for fast installation
For laying in rail vehicles and buses
Cable designation
2YY(ST)CY2Y2x2x0.64/1.50-100
-
Electrical data
Damping ratio per length
• at 10 MHz
0.063 dB/m
0.053 dB/m
• at 100 MHz
0.213 dB/m
0.188 dB/m
Impedance for frequency range
1 MHz … 100 MHz
100
100
Relative symmetrical tolerance
of the surge impedance
at 1 MHz … 100 MHz
5 %
5 %
Near-end crosstalk per length
at 1 MHz ... 100 MHz
0.5 dB/m
0.5 dB/m
Transfer impedance at 10 MHz
10 m
/m
8 m
/m
Loop resistance per length
124
/km
124
/km
Operating voltage RMS value
100 V
125 V
percentage NVP value
64 %
-
Mechanical data
Number of electrical wires
4
4
Design of shield
Overlapped aluminum-clad foil, sheathed in a braided
screen of tin-plated copper wires
Overlapped aluminum-clad foil, sheathed in a braided
screen of tin-plated copper wires
Design of the electrical connection
FastConnect
Yes
No
AWG number
-
-
Core diameter of the AWG22 core
0.64 mm
0.75 mm
Outer diameter
• of the inner conductor
0.64 mm
0.75 mm
• of the wire insulation
1.5 mm
1.5 mm
• of the inner sheath of the cable
4 mm
-
• of the cable sheath
9 mm
6.6 mm
Symmetrical tolerance
of outer diameter of cable sheath
0.2 mm
0.2 mm
Outer diameter of the cable sheath
Note
Cable diameter > 6.5 mm due to additional PE protective
jacket. Cable can only be connected in the
RJ45/M12 connector after stripping the protective jacket.
-
Material
• of the wire insulation
PE
PE
• of the inner sheath of the cable
PVC
-
• of the cable sheath
PVC
Elastomer meshed electron beam
Color
• of the insulation of data wires
white / yellow / blue / orange
white / yellow / blue / orange
• of the cable sheath
Black
Black
Bending radius
• with single bend
80 mm
40 mm
• with multiple bends
80 mm
40 mm
Traction stress maximum
150 N
150 N
Weight per length
97 kg/km
71 kg/km
© Siemens AG 2014