2/58
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 2 x 2
Permitted ambient conditions
Ambient temperature
• during operating
-40 … +80 °C
-25 … +75 °C
-40 … +75 °C
-40 … +75 °C
• during storage
-40 … +80 °C
-25 … +75 °C
-50 … +75 °C
-50 … +75 °C
• during transport
-40 … +80 °C
-25 … +75 °C
-50 … +75 °C
-50 … +75 °C
• during installation
-20 … +60 °C
-10 … +60 °C
-20 … +60 °C
-20 … +60 °C
Burning behaviour
flame resistant according to
IEC 60332-1-2
flame resistant according to
UL 1685 (CSA FT 4)
flame resistant according to
IEC 60332-1-2
flame resistant according to
UL 1685 (CSA FT 4)
Chemical resistance
• to mineral oil
oil resistant according to
IEC 60811-2-1 (7x24h/90°C)
Conditional resistance
oil resistant according to
IEC 60811-2-1 (7x24h/90°C)
Conditional resistance
• to grease
Resistant
Conditional resistance
Resistant
Conditional resistance
• to water
Resistant
Conditional resistance
resistant
Conditional resistance
Radiological resistance
to UV radiation
Resistant
Resistant
Resistant
Resistant
Product properties, functions,
components
general
Product feature
• halogen-free
Yes
No
Yes
No
• silicon-free
Yes
Yes
Yes
Yes
Cable length with 100BaseTX for
Industrial Ethernet
55 m
85 m
85 m
85 m
Standards, specifications,
approvals
UL/ETL listing with 300 V rating
Yes: UL Style 21161
Yes: c(UL)us, CMG / PLTC /
Sun Res / OIL RES
Yes: cULus / CMX
Yes: c(UL)us, CMG / PLTC /
Sun Res / OIL RES
UL/ETL style with 600 V rating
No
yes
No
yes
Verification of suitability
• CE mark
Yes
Yes
Yes
Yes
• RoHS conformity
-
Yes
Yes
Yes
Standard for structured cabling
Cat5e
Cat5e
Cat5e
Cat5e
Marine classification association
• American Bureau of Shipping Eu-
rope Ltd. (ABS)
No
No
No
No
• Bureau Veritas (BV)
No
No
No
No
• Det Norske Veritas (DNV)
No
No
No
No
• Germanische Lloyd (GL)
No
No
No
No
• Lloyds Register of Shipping (LRS)
No
No
No
No
Article No.
6XV1870-2F
6XV1870-2D
6XV1840-3AH10
6XV1871-2S
Product-type designation
IE TP Torsion Cable 2 x 2
(Type C)
IE FC TP Trailing Cable GP
2 x 2 (Type C)
IE FC TP Trailing Cable
2 x 2 (Type C)
IE FC TP Festoon Cable GP
2 x 2 (Type B)
© Siemens AG 2014