Technical specifications
(continued)
PROFINET/Industrial Ethernet
Cabling technology
IE FC TP Cable 2 x 2
Article No.
6XV1870-2F
6XV1870-2D
6XV1840-3AH10
6XV1871-2S
Product-type designation
IE TP Torsion Cable 2 x 2
(Type C)
IE FC TP Trailing Cable GP
2 x 2 (Type C)
IE FC TP Trailing Cable
2 x 2 (Type C)
IE FC TP Festoon Cable GP
2 x 2 (Type B)
Product description
Highly flexible bus cable
(4-core), sold by the meter,
not assembled
Patch cable, preferred
length, pre-assembled with
a 15-pole Sub-D connector
and a RJ45 connector
Highly flexible bus cable
(4-core), sold by the meter,
not assembled
Flexible bus cable (4-core),
sold by the meter,
not assembled
Acceptability for application
Continuous motion control
when using robots
Continuous motion control
in a cable carrier
Continuous motion control
in a cable carrier
For continuous motion
in a trailing cable,
festoon mounting
Cable designation
02YS C11Y 1x4x0,75/1,5-100
LI VZN FRNC GN
2YY (ST) CY 2x2x0,75/1,5-
100 LI GN
2YH (ST) C11Y 2x2x0,75/1,5-
100 LI GN VZN FRNC
2YY (ST) CY 2x2x0,75/1,5 LI
GN
Electrical data
Damping ratio per length
• at 10 MHz
81 dB/km
63 dB/km
60 dB/km
63 dB/km
• at 100 MHz
410 dB/km
213 dB/km
220 dB/km
213 dB/km
Impedance for frequency range
1 MHz … 100 MHz
100
100
100
100
Relative symmetrical tolerance
of the surge impedance
at 1 MHz … 100 MHz
15 %
5 %
15 %
5 %
Near-end crosstalk per length
at 1 MHz ... 100 MHz
0.5 dB/m
500 dB/km
500 dB/km
500 dB/km
Transfer impedance at 10 MHz
100 m
/m
20 m
/m
10 m
/m
100 m
/m
Loop resistance per length
120
/km
0.12
/m
0.12
/m
0.12
/m
Insulation resistance coefficient
-
-
-
-
Operating voltage RMS value
100 V
100 V
100 V
100 V
Percentage NVP value
70 %
66 %
66 %
66 %
Mechanical data
Number of electrical wires
4
4
4
4
Design of shield
Overlapped aluminum-clad
foil, sheathed in a braided
screen of tin-plated copper
wires
Overlapped aluminum-clad
foil, sheathed in a braided
screen of tin-plated copper
wires
Overlapped aluminum-clad
foil, sheathed in a braided
screen of tin-plated copper
wires
Overlapped aluminum-clad
foil, sheathed in a braided
screen of tin-plated copper
wires
Design of the electrical connection
FastConnect
No
Yes
Yes
Yes
Core diameter of the AWG22 core
0.76 mm
0.75 mm
0.75 mm
0.75 mm
Outer diameter
• of the inner conductor
0.76 mm
0.75 mm
0.75 mm
0.75 mm
• of the wire insulation
1.5 mm
1.5 mm
1.5 mm
1.5 mm
• of the inner sheath of the cable
-
3.9 mm
3.9 mm
3.9 mm
• of the cable sheath
6.5 mm
6.5 mm
6.5 mm
6.5 mm
Symmetrical tolerance of outer diame-
ter of cable sheath
0.2 mm
0.2 mm
0.2 mm
0.2 mm
Material
• of the wire insulation
PE
PE
PE
PE
• of the inner sheath of the cable
-
PVC
FRNC
PVC
• of the cable sheath
PUR (TPE-U)
PVC
PUR (TPE-U)
PVC
Color
• of the insulation of data wires
white / yellow / blue / orange
white / yellow / blue / orange
white / yellow / blue / orange
white / yellow / blue / orange
• of the cable sheath
green
green
green
green
Bending radius
• with single bend
32.5 mm
32.5 mm
19.5 mm
30 mm
• with multiple bends
65 mm
49 mm
49 mm
70 mm
• with continuous bending
-
100 mm
100 mm
70 mm
Number of bending cycles
-
3 000 000
4 000 000
5 000 000
• Note
Not suitable for installation
in festoons
For use in cable carriers,
for 3 million bending cycles
with a bending radius of
100 mm, a speed of 4 m/s,
and an acceleration of 4 m/s²
For use in cable carriers,
for 4 million bending cycles
with a bending radius of
100 mm, a speed of 4 m/s,
and an acceleration of 4 m/s²
5 million bending cycles
for a bending radius of
70 mm and an acceleration
of 4 m/s²
Number of torsion cycles with torsion
by ± 180° on 1 m cable length
5 000 000
-
-
-
Traction stress maximum
130 N
150 N
150 N
150 N
Weight per length
54 kg/km
68 kg/km
63 kg/km
68 kg/km