SIEMENS
2/241
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200IRT managed
Product functions
Diagnosis
Product function
• Port diagnostics
Yes
Yes
Yes
• Statistics packet size
Yes
Yes
Yes
• Statistics packet type
Yes
Yes
Yes
• Error Statistics
Yes
Yes
Yes
Product functions
DHCP
Product function DHCP client
Yes
Yes
Yes
Product functions
Redundancy
Product function
• Ring redundancy
Yes
Yes
Yes
• Redundancy manager
Yes
Yes
Yes
• Standby redundancy
Yes
Yes
Yes
• High Speed Redundancy Protocol
(HRP)
Yes
Yes
Yes
• Media Redundancy Protocol
(MRP)
Yes
Yes
Yes
• Parallel Redundancy Protocol
(PRP)
No
No
No
• Passive listening
Yes
Yes
Yes
Protocol is supported PRP
Yes
Yes
Yes
Product functions
Security
Protocol is supported SSH
Yes
Yes
Yes
Product functions
Time
Product function SICLOCK support
Yes
Yes
Yes
Protocol is supported
• NTP
No
No
No
• SNTP
Yes
Yes
Yes
Standards, specifications,
approvals
Standard
• for EMC from FM
FM3611: Class 1, Division 2, Group A,
B, C, D / T4, CL.1, Zone 2, GP. IIC, T4
FM3611: Class 1, Division 2, Group A,
B, C, D / T4, CL.1, Zone 2, GP. IIC, T4
FM3611: Class 1, Division 2, Group A,
B, C, D / T4, CL.1, Zone 2, GP. IIC, T4
• for hazardous zone
EN 60079-0 : 2006,
EN 60079-15: 2005, II 3 G Ex nA II T4
KEMA 07 ATEX 0145X
EN 60079-0 : 2006,
EN 60079-15: 2005, II 3 G Ex nA II T4
KEMA 07 ATEX 0145X
EN 60079-0 : 2006,
EN 60079-15: 2005, II 3 G Ex nA II T4
KEMA 07 ATEX 0145X
• for safety of CSA and UL
UL 60950-1, CSA C22.2 No. 60950-1
UL 60950-1, CSA C22.2 No. 60950-1
UL 60950-1, CSA C22.2 No. 60950-1
• for hazardous area of CSA and UL
ANSI / ISA 12.12.01, CSA C22.2 No.
213-M1987, CL. 1 / Div. 2 / GP. A, B, C,
D T4, CL. 1 / Zone 2 / GP. IIC, T4
ANSI / ISA 12.12.01, CSA C22.2 No.
213-M1987, CL. 1 / Div. 2 / GP. A, B, C,
D T4, CL. 1 / Zone 2 / GP. IIC, T4
ANSI / ISA 12.12.01, CSA C22.2 No.
213-M1987, CL. 1 / Div. 2 / GP. A, B, C,
D T4, CL. 1 / Zone 2 / GP. IIC, T4
• for emitted interference
EN 61000-6-4:2001 (Class A)
EN 61000-6-4:2001 (Class A)
EN 61000-6-4:2001 (Class A)
• for interference immunity
EN 61000-6-4:2001
EN 61000-6-4:2001
EN 61000-6-4:2001
Verification of suitability
EN 61000-6-4:2001
EN 61000-6-4:2001
EN 61000-6-4:2001
• CE-mark
Yes
Yes
Yes
• C-Tick
Yes
Yes
Yes
• KC approval
Yes
Yes
Yes
• Railway application in accordance
with EN 50155
No
No
No
• Railway application in accordance
with EN 50124-1
No
No
No
Marine classification association
• American Bureau
of Shipping Europe Ltd. (ABS)
No
No
No
• Bureau Veritas (BV)
Yes
No
No
• Det Norske Veritas (DNV)
Yes
No
No
• Germanische Lloyd (GL)
Yes
No
No
• Lloyds Register of Shipping (LRS)
Yes
No
No
• Nippon Kaiji Kyokai (NK)
Yes
No
No
• Polski Rejestr Statkow (PRS)
No
No
No
Article No.
6GK5204-0JA00-2BA6
6GK5202-2JR00-2BA6
6GK5201-3JR00-2BA6
Product-type designation
SCALANCE X204IRT PRO
SCALANCE X202-2P IRT PRO
SCALANCE X201-3P IRT PRO
© Siemens AG 2014