SIEMENS
2/198
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-200 managed
Product functions
Diagnosis
Product function
• Port diagnostics
Yes
Yes
Yes
• Statistics packet size
Yes
Yes
Yes
• Statistics packet type
Yes
Yes
Yes
• Error statistics
Yes
Yes
Yes
Product functions
DHCP
Product function DHCP client
Yes
Yes
Yes
Product functions
Redundancy
Product function
• Ring redundancy
Yes
Yes
Yes
• Redundancy manager
Yes
Yes
Yes
• Standby redundancy
No
No
No
• High Speed Redundancy Protocol
(HRP)
Yes
Yes
Yes
• Media Redundancy Protocol (MRP)
Yes
Yes
Yes
• Parallel Redundancy Protocol (PRP)
No
No
No
• Passive listening
Yes
Yes
Yes
Protocol is supported PRP
Yes
Yes
Yes
Product functions
Security
Protocol is supported SSH
Yes
Yes
Yes
Product functions
Time
Product function
• SICLOCK support
Yes
Yes
Yes
Protocol is supported
• NTP
No
No
No
• SNTP
Yes
Yes
Yes
Standards, specifications,
approvals
Standard
• for EMC from FM
FM3611: Class 1, Division 2, Group A,
B, C, D / T4, CL.1, Zone 2, GP. IIC, T4
FM3611: Class 1, Division 2, Group A,
B, C, D / T4, CL.1, Zone 2, GP. IIC, T4
FM3611: Class 1, Division 2, Group A,
B, C, D / T4, CL.1, Zone 2, GP. IIC, T4
• for hazardous zone
EN 60079-0: 2006,
EN 60079-15: 2005, II 3 (2) G Ex nA
[op is] IIC T4, KEMA 07 ATEX 0145 X
EN 60079-0 : 2006,
EN 60079-15: 2005, II 3 G Ex nA II T4
KEMA 07 ATEX 0145X
EN 60079-0: 2006,
EN 60079-15: 2005, II 3 (2) G Ex nA
[op is] IIC T4, KEMA 07 ATEX 0145 X
• for safety of CSA and UL
UL 60950-1, CSA C22.2 No. 60950-1
UL 60950-1, CSA C22.2 No. 60950-1
UL 60950-1, CSA C22.2 No. 60950-1
• for hazardous area of CSA and UL
ANSI / ISA 12.12.01, CSA C22.2 No.
213-M1987, CL. 1 / Div. 2 / GP. A, B, C,
D T4, CL. 1 / Zone 2 / GP. IIC, T4
ANSI / ISA 12.12.01, CSA C22.2 No.
213-M1987, CL. 1 / Div. 2 / GP. A, B, C,
D T4, CL. 1 / Zone 2 / GP. IIC, T4
ANSI / ISA 12.12.01, CSA C22.2 No.
213-M1987, CL. 1 / Div. 2 / GP. A, B, C,
D T4, CL. 1 / Zone 2 / GP. IIC, T4
• for emitted interference
EN 61000-6-4:2001 (Class A)
EN 61000-6-4 (Class A)
EN 61000-6-4 (Class A)
• for interference immunity
EN 61000-6-4:2001
EN 61000-6-2
EN 61000-6-2
Verification of suitability
EN 61000-6-4:2001
EN 61000-6-2, EN 61000-6-4
EN 61000-6-2, EN 61000-6-4
• CE mark
Yes
Yes
Yes
• C-Tick
Yes
Yes
Yes
• KC approval
Yes
Yes
Yes
• Railway application in accordance
with EN 50155
No
No
Yes
• Railway application in accordance
with EN 50124-1
No
No
No
Marine classification association
• American Bureau of Shipping Eu-
rope Ltd. (ABS)
Yes
Yes
No
• Bureau Veritas (BV)
Yes
Yes
No
• Det Norske Veritas (DNV)
Yes
Yes
No
• Germanische Lloyd (GL)
Yes
Yes
No
• Lloyds Register of Shipping (LRS)
Yes
Yes
No
• Nippon Kaiji Kyokai (NK)
Yes
Yes
No
• Polski Rejestr Statkow (PRS)
Yes
Yes
No
Article No.
6GK5204-2BB10-2AA3
6GK5204-2BC10-2AA3
6GK5204-2BB10-2CA2
Product-type designation
SCALANCE X204-2
SCALANCE X204-2LD
SCALANCE X204-2TS
© Siemens AG 2014