SIEMENS
2/180
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE X-100 unmanaged
Permitted ambient conditions
Ambient temperature
• during operating
-10 … +60 °C
-10 … +60 °C
-20 … +70 °C
-20 … +60 °C
• during storage
-40 … +80 °C
-40 … +80 °C
-40 … +80 °C
-40 … +80 °C
• during transport
-40 … +80 °C
-40 … +80 °C
-40 … +80 °C
-40 … +80 °C
Relative humidity at 25 °C without
condensation during operating maxi-
mum
95 %
95 %
95 %
95 %
Protection class IP
IP30
IP30
IP30
IP30
Design, dimensions and weight
Design
compact
compact
compact
compact
Width
60 mm
60 mm
60 mm
60 mm
Height
125 mm
125 mm
125 mm
125 mm
Depth
124 mm
124 mm
124 mm
124 mm
Net weight
0.78 kg
0.78 kg
0.78 kg
0.9 kg
Mounting type
• 35 mm DIN rail mounting
Yes
Yes
Yes
Yes
• wall mounting
Yes
Yes
Yes
Yes
• S7-300 rail mounting
Yes
Yes
Yes
Yes
Mounting type
-
-
-
-
Standards, specifications,
approvals
Standard
• for EMC from FM
FM3611: Class 1, Division 2,
Group A, B, C, D / T..,
Class 1, Zone 2,
Group IIC, T..
FM3611: Class 1, Division 2,
Group A, B, C, D / T..,
Class 1, Zone 2,
Group IIC, T..
FM3611: Class 1, Division 2,
Group A, B, C, D / T..,
Class 1, Zone 2,
Group IIC, T..
FM3611: Class 1, Division 2,
Group A, B, C, D / T..,
Class 1, Zone 2,
Group IIC, T..
• for hazardous zone
EN 60079-0: 2006,
EN 60079-15: 2005, II 3 G Ex
nA IIT.., KEMA 07
ATEX 0145 X
EN 60079-0: 2006,
EN 60079-15: 2005, II 3 G Ex
nA IIT.., KEMA 07
ATEX 0145 X
EN 60079-0: 2006,
EN 60079-15: 2005, II 3 G Ex
nA IIT.., KEMA 07
ATEX 0145 X
EN 60079-0: 2006,
EN 60079-15: 2005, II 3 G Ex
nA IIT.., KEMA 07
ATEX 0145 X
• for safety of CSA and UL
UL 60950-1,
CSA C22.2 No. 60950-1
UL 60950-1,
CSA C22.2 No. 60950-1
UL 60950-1,
CSA C22.2 No. 60950-1
UL 60950-1,
CSA C22.2 No. 60950-1
• for hazardous area of CSA and UL
UL 1604 and UL 2279-15
(Hazardous Location),
Class 1 / Division 2 / Group
A, B, C, D / T.., Class 1 /
Zone 2 / Group IIC / T..
UL 1604 and UL 2279-15
(Hazardous Location),
Class 1 / Division 2 / Group
A, B, C, D / T.., Class 1 /
Zone 2 / Group IIC / T..
UL 1604 and UL 2279-15
(Hazardous Location),
Class 1 / Division 2 / Group
A, B, C, D / T.., Class 1 /
Zone 2 / Group IIC / T..
UL 1604 and UL 2279-15
(Hazardous Location),
Class 1 / Division 2 / Group
A, B, C, D / T.., Class 1 /
Zone 2 / Group IIC / T..
• for emitted interference
EN 61000-6-4 (Class A)
EN 61000-6-4 (Class A)
EN 61000-6-4 (Class A)
EN 61000-6-4:2001
• for interference immunity
EN 61000-6-2
EN 61000-6-2
EN 61000-6-2
EN 61000-6-2:2001
Verification of suitability
EN 61000-6-2,
EN 61000-6-4
EN 61000-6-2,
EN 61000-6-4
EN 61000-6-2,
EN 61000-6-4
EN 61000-6-2:2001,
EN 61000-6-4:2001
• CE mark
Yes
Yes
Yes
Yes
• C-Tick
Yes
Yes
Yes
Yes
• KC approval
Yes
Yes
Yes
Yes
Marine classification association
• American Bureau
of Shipping Europe Ltd. (ABS)
Yes
Yes
Yes
No
• Bureau Veritas (BV)
Yes
Yes
Yes
No
• Det Norske Veritas (DNV)
Yes
Yes
Yes
No
• Germanische Lloyd (GL)
Yes
Yes
Yes
No
• Lloyds Register of Shipping (LRS)
Yes
Yes
Yes
No
• Nippon Kaiji Kyokai (NK)
Yes
Yes
Yes
No
• Polski Rejestr Statkow (PRS)
Yes
Yes
Yes
No
Article No.
6GK5104-2BB00-2AA3
6GK5106-1BB00-2AA3
6GK5108-0BA00-2AA3
6GK5108-0PA00-2AA3
Product-type designation
SCALANCE X104-2
SCALANCE X106-1
SCALANCE X108
SCALANCE X108PoE
© Siemens AG 2014