SIEMENS
2/169
Siemens IK PI · 2015
PROFINET/Industrial Ethernet
Industrial Ethernet Switches
SCALANCE XB-000 unmanaged
2
■
Technical specifications
Article No.
6GK5004-1BD00-1AB2
6GK5004-1BF00-1AB2
6GK5005-0BA00-1AB2
6GK5008-0BA00-1AB2
Product-type designation
SCALANCE XB004-1
SCALANCE XB004-1LD
SCALANCE XB005
SCALANCE XB008
Transmission rate
Transfer rate 1
10 Mbit/s
10 Mbit/s
10 Mbit/s
10 Mbit/s
Transfer rate 2
100 Mbit/s
100 Mbit/s
100 Mbit/s
100 Mbit/s
Interfaces
Number of electrical/optical connec-
tions for network components
or terminal equipment maximum
5
5
5
8
Number of electrical connections
• for network components
• and terminal equipment
4
4
5
8
• for power supply
1
1
1
1
Design of electrical connection
• for network components and
terminal equipment
RJ45 port
RJ45 port
RJ45 port
RJ45 port
• for power supply
3-pole terminal block
3-pole terminal block
3-pole terminal block
3-pole terminal block
Number of optical interfaces
for optical waveguide
• at 100 Mbit/s
1
1
-
-
Design of optical interface
for optical waveguide
• at 100 Mbit/s
SC port
(multimode up to 5 km)
SC port
(singlemode up to 26 km)
-
-
Connectable optical power
relative to 1 mW
• of the transmitter output
-19 … -14 dB
-5 … +0 dB
- -
- -
• of the receiver input maximum
-14 dB
0 dB
-
-
Optical sensitivity relative to 1 mW of
the receiver input minimum
-32 dB
-34 dB
-
-
Attenuation of fiber-optic cable trans-
mission link minimum necessary
0 dB
0 dB
-
-
Range at the optical interface
depending on the optical fiber used
0 … 5 km
0 … 26 km
- -
- -
Supply voltage,
current consumption, power loss
Type of supply voltage
DC
DC
DC
DC
Supply voltage external
24 V
24 V
24 V
24 V
• minimum
19.2 V
19.2 V
19.2 V
19.2 V
• maximum
28.8 V
28.8 V
28.8 V
28.8 V
Product component fusing at power
supply input
Yes
Yes
Yes
Yes
Type of fusing at input for supply
voltage
0.6 A / 60 V
0.6 A / 60 V
0.6 A / 60 V
0.6 A / 60 V
Consumed current maximum
0.11 A
0.1 A
0.07 A
0.12 A
Active power loss at 24 V for DC
2.64 W
2.4 W
1.68 W
2.88 W
Permitted ambient conditions
Ambient temperature
• during operating
-10 … +60 °C
-10 … +60 °C
-10 … +60 °C
-10 … +60 °C
• during storage
-40 … +80 °C
-40 … +80 °C
-40 … +80 °C
-40 … +80 °C
• during transport
-40 … +80 °C
-40 … +80 °C
-40 … +80 °C
-40 … +80 °C
Relative humidity at 25 °C without
condensation during operating
maximum
95 %
95 %
95 %
95 %
Protection class IP
IP20
IP20
IP20
IP20
© Siemens AG 2014