SIEMENS
2/145
Siemens IK PI · 2015
2
■
Technical specifications
(continued)
PROFINET/Industrial Ethernet
SCALANCE X-100 unmanaged / Media converters
SCALANCE X-100 unmanaged media converters
Permitted ambient conditions
Ambient temperature
• during operating
-10 … +60 °C
-10 … +60 °C
-10 … +60 °C
• during storage
-40 … +80 °C
-40 … +80 °C
-40 … +80 °C
• during transport
-40 … +80 °C
-40 … +80 °C
-40 … +80 °C
Relative humidity at 25 °C without
condensation during operating
maximum
95 %
95 %
95 %
Protection class IP
IP30
IP30
IP30
Design, dimensions and weight
Design
Compact
Compact
Compact
Width
40 mm
40 mm
40 mm
Height
125 mm
125 mm
125 mm
Depth
124 mm
124 mm
124 mm
Net weight
0.55 kg
0.55 kg
0.56 kg
Mounting type
• 35 mm DIN rail mounting
Yes
Yes
Yes
• wall mounting
Yes
Yes
Yes
• S7-300 rail mounting
Yes
Yes
Yes
Mounting type
Standards, specifications,
approvals
Standard
• for EMC from FM
FM3611: Class 1, Division 2, Group A,
B, C, D / T.., Class 1, Zone 2,
Group IIC, T..
FM3611: Class 1, Division 2, Group A,
B, C, D / T.., Class 1, Zone 2,
Group IIC, T..
FM3611: Class 1, Division 2, Group A,
B, C, D / T.., Class 1, Zone 2,
Group IIC, T..
• for hazardous zone
EN 600079-15 II 3 G EEx nA II T..
KEMA 06 ATEX 0021 X
EN 600079-15 II 3 G EEx nA II T..
KEMA 06 ATEX 0021 X
EN 600079-15 II 3 G EEx nA II T..
KEMA 06 ATEX 0021 X
• for safety of CSA and UL
UL 60950-1, CSA C22.2 No. 60950-1
UL 60950-1, CSA C22.2 No. 60950-1
UL 60950-1, CSA C22.2 No. 60950-1
• for hazardous area of CSA and UL
UL 1604 and UL 2279-15
(Hazardous Location), Class 1 /
Division 2 / Group A, B, C, D / T..,
Class 1 / Zone 2 / Group IIC / T..
UL 1604 and UL 2279-15
(Hazardous Location), Class 1 /
Division 2 / Group A, B, C, D / T..,
Class 1 / Zone 2 / Group IIC / T..
UL 1604 and UL 2279-15
(Hazardous Location), Class 1 /
Division 2 / Group A, B, C, D / T..,
Class 1 / Zone 2 / Group IIC / T..
• for emitted interference
EN 61000-6-3 (Class B)
EN 61000-6-3
EN 61000-6-4:2001
• for interference immunity
EN 61000-6-4:2001
EN 61000-6-4:2001
EN 61000-6-4:2001
Verification of suitability
EN 61000-6-2:2001,
EN 61000-6-4:2001
EN 61000-6-2:2001,
EN 61000-6-4:2001
EN 61000-6-2:2001,
EN 61000-6-4:2001
• CE mark
Yes
Yes
Yes
• C-Tick
Yes
Yes
Yes
• KC approval
Yes
Yes
Yes
Marine classification association
• American Bureau of Shipping
Europe Ltd. (ABS)
Yes
Yes
Yes
• Bureau Veritas (BV)
Yes
Yes
Yes
• Det Norske Veritas (DNV)
Yes
Yes
Yes
• Germanische Lloyd (GL)
Yes
Yes
Yes
• Lloyds Register of Shipping (LRS)
Yes
Yes
Yes
• Nippon Kaiji Kyokai (NK)
Yes
Yes
Yes
• Polski Rejestr Statkow (PRS)
No
No
No
Article No.
6GK5101-1BH00-2AA3
6GK5101-1BY00-2AA3
6GK5101-1BX00-2AA3
Product-type designation
SCALANCE X101-1POF
SCALANCE X101-1FL
SCALANCE X101-1AUI
© Siemens AG 2014