![](https://www.globalindustrialsupplies.eu/wp-content/uploads/2016/08/siemens-gallery-4-324x200.jpg)
2/9
Siemens CR 1 · 2015
2
SIMOCRANE Standard Technology
SIMOCRANE Basic Technology
Hardware SIMOTION D435-2 Control Unit
■
Design
Interfaces
Display and diagnostics
•
LEDs to display operating states and errors
•
3 measuring sockets
•
Service switch and mode selector
•
Diagnostics button
Onboard I/O
•
12 digital inputs
•
16 digital inputs/outputs (max. 16 as high-speed measuring
inputs, max. 8 as high-speed output cams)
Communication
•
6 × DRIVE-CLiQ
•
2 × Industrial Ethernet (3
× Industrial Ethernet for D4x5-2 DP),
of which one interface easily accessible at the module front
• 2 × PROFIBUS DP
•
1 × PROFINET IO (1 interface with 3 ports, with D4x5-2 DP/PN
only)
•
2 × USB
Data backup
•
1 × slot for SIMOTION CompactFlash card
Further interfaces
•
Terminals for 24 V electronics power supply
Option modules
With the TB30 Terminal Board, the SIMOTION D4x5-2 Control
Units can be extended with 4 digital inputs, 4 digital outputs, 2
analog inputs and 2 analog outputs. The TB30 Terminal Board is
plugged into the option slot on the Control Unit. Using the
CBE30-2 Communication Board for PROFINET IO, it is possible
to equip the SIMOTION D435-2 DP/PN Control Units with a 2nd
PROFINET interface with 4 ports.
Applications for a 2nd PROFINET interface:
•
2 separate networks (e.g. one local and one higher-level
network)
•
Address space can be doubled to 2 × 4 Kbyte
•
Maximum number of connectable devices can be doubled to
2 × 64
•
Separated to create a fast and a slow bus system/execution
system to efficiently utilize the control performance
- PROFINET onboard: SERVO
Fast
and IPO
Fast
- PROFINET via CBE30-2: SERVO/IPO/IPO2
■
Integration
Connection overview SIMOTION D4x5-2
The maximum permissible cable lengths should be taken into
account when planning the cable layout. Functional faults can
occur when using longer cables. The permissible length of
PROFIBUS DP cables depends on the configuration. The
DRIVE-CLiQ cables used for the SINAMICS S120 CU320-2
Control Unit can also be used for SIMOTION D4x5-2
Control Units.
6ES7901-4BD00-0XA0
not
D425-2
Ethernet
USB
DRIVE-
CLiQ
Ethernet
node
12 DI, 16 DI/DO
SINAMICS S120
drive components
24 V supply
Programming
device (PG)
USB memory
stick
PROFIBUS DP
node
DRIVE-CLiQ cable
Ethernet cable
PROFIBUS cables
Onboard
I/Os
Power
supply
PROFINET IO
2)
CBE30-2
(optional)
e.g. SINAMICS
S120, ET 200SP
PROFINET IO
IRT/RT I/Os
e.g. SINAMICS
S120, ET 200SP
PROFINET IO
IRT/RT I/Os
G_PM10_EN_00216b
1)
X120 only for D4x5-2 DP.
2)
D4x5-2 DP/PN only (CBE30-2 as second PROFINET interface).
3)
D4x5-2 DP/PN only.
1)
X100
to
X103
X104
X105
SIMOTION
D4x5-2
X122
X132
X142
X124
X136
PROFIBUS DP
X126
X135
X125
X150 P1
P2
P3
X1400 P1
P2
P3
P4
X120 P1
X127 P1
X130 P1
PROFINET IO
3)
© Siemens AG 2015