< Previous Sew Eurodrive products | Products index | Next Sew Eurodrive products >
Explosion-proof AC asynchronous motors in combination with frequency inverters
03
Features | Overview of the advantages of this combination over AC asynchronous motors in protection type “d” (EN 60079-1; flameproof enclosure): – High efficiency – Lighter weight – Shortest possible delivery times, high availability – Certified for operation with SEW frequency inverters – Suitable for pump and fan drives – Delivery from a single source, from a manufacturer that offers both components itself – Higher speeds Strict adherence to guidelines is particularly important in areas with potentially explosive gas/air and dust/air mixtures. Thanks to many years of experience and competency in this area, SEW-EURODRIVE ensures that the relevant guidelines are observed. Furthermore, the company’s expertise is continually being expanded to include new and further developments. |
Certifications | – The 4-pole motors from SEW-EURODRIVE are also suited for operation on frequency inverters according to ATEX, IECEx, and HazLoc-NA – Category 2 and EPL b and c are certified by prototype testing – Motors are certified to HazLoc-NA by CSA – In category 3 and division 2, brakemotors are also available – The suitability for operation on inverters is confirmed on the nameplate – A second nameplate provides all the information required for operation |
Zone | Motor type | Protection type | MOVITRAC B | MOVIDRIVE B | MOVIMOT |
1 | EDR../2GD | “e” (EN 60079-7, incre- ased safety) | ✓* | ✓ | – |
2 | EDR../3GD | “na” (EN 60079-15, non-sparking) | ✓* | ✓* | – |
21 | EDR../2GD | “tb” (EN 60079-31, dust explosion protection) | ✓* | ✓ | – |
22 | EDR../3GD | “tc” (EN 60079-31, dust explosion protection) | ✓* | ✓* | ✓* |
EDR../3D |
* also in field weakening range operation