DecentraLized MOV±SAFE
®
HM31 safety controLLer
Can be used with MOV±PRO
®
F
eatures and beneIts
–
Scalable safety technology for decentralized application inverter for simple and complex safety
functions
–
Reduced wiring work through the integration of functional safety technology
–
Short total response times of the application due to direct monitoring and disconnection
–
Very easy startup and validation of axis safety functions
–
Flexible con²guration and validation of complex, application-speci²c safety functions
–
Stand-alone safety solutions in independent operation without external safety controller possible
–
Long product life of the safety components due to long service life (20 years)
–
Easy integration of safe drive technology in existing plants with PROFIsafe communication
–
Universal application in a PROFIsafe network via PROFIBUS and PROFINET IO
–
Certi²ed to (IEC 61508) SIL 3, (EN ISO 13849-1) PL e
Simple project planning with
MOV±PRO
®
SDC / ADC
–
Control via PROFIsafe with PROFIsafe option S11
–
Optional, safety-related brake disconnection (SBC)
–
The integrated PROFIsafe option S11 comes equipped with 4 safety-related inputs for
connecting safe sensors and 2 safety-related outputs
SpeciIc MOV±PRO
®
design with expanded
functions as drive and system controller for
MAXOLUT±ON
®
system solutions
–
Decentralized MOVISAFE
®
HM31 safety controller
–
Free programming according to IEC 61131-3 per “drag & drop” using certi²ed function modules
(Motion Library PFF-HM31) and the “SILworX” engineering tool
–
Ready-to-use drive and application modules (Motion Library, SIL 3 or PL e certi²ed) are available
based on IEC 61800-5-2 for mobile materials handling technology
- SS1, SS2, SOS, SDI, SLS, SSR, SLA, SAR, SSM, SLI, SLP
- Safe disconnection and stopping
- Safe range changeover
- Safe movement and position detection
Hardware assignment:
–
24 safe digital inputs (8 OSSD-capable) and 8 safe sinking/sourcing digital outputs
–
Safe counter inputs (HTL, TTL)
–
CAN and RS485 interfaces
Certi²cation:
–
SIL 3 according to IEC 61508
–
PL e according to EN ISO 13849-1
Safe communication:
–
safeethernet (SIL 3, master & slave), also possible via WLAN
–
PROFINET PROFIsafe (controller/host & device/device)
Application examples
Electri²ed monorail systems for heavy loads, automated guided vehicle, scissor lift tables,
lifting/lowering conveyors, lifting stations, transfer carriages, rotary feeders, rotary indexing tables,
high-speed horizontal conveyors with positioning