SEW EURODRIVE
143
Project pLanning
Project planning is the basic requirement for safe operation of explosion-proof motors.
EDRS.. and EDRE.. motors meet the de²ned requirements for use in potentially explosive
atmospheres of the Directive 2014/34/EU (ATEX), IECEx and HazLoc-NA
®
Division 2. A device for
direct temperature monitoring in combination with the de²ned parameters of the frequency inverter
offers the best possible protection against excessive heating caused by overload.
TechnicaL data
EDR.. motors 230 / 400 V
Connection
Star
Delta
P
line
kW
M
FI
Nm
M
FI
Nm
Category 2G / 2D / EPL b / Div. 2
0.25 – 37
1.7 – 240
1.7 – 240
Category 3G / 3D / EPL c / Div. 2
Category 3D with MOVIMOT
®
0.25 – 3.0
1.7 – 20,5
1.2 – 9.9
For frequency inverter operation, there is no reduced load value in relation to the nominal line torque to ensure thermally safe operation as is often usual.
03