SEW EURODRIVE
251
Function level
Indicates the functional scope of the software assigned to the MOVIFIT
®
devices regarding
–
Software functionality
–
Processing of digital inputs and outputs
–
Local system control
–
Startup, operation, and diagnostics
MOVIFIT
®
FC Classic
standard inverters
Simple and standardized functions
MOVIFIT
®
FC Technology application
inverters
Parameterizable application modules:
–
Standardized functions
–
Control and diagnostics via fieldbus
–
Parameterization instead of programming
–
Startup and diagnostics using MOVITOOLS
®
MotionStudio
–
“Easy mode”: Easy startup using
DIP switches possible
–
Standardized drive functions
–
Control as fieldbus gateway
–
Extended configuration and diagnostics op-
tions via gateway configurator
Free programming (MOVI-PLC
®
/
MOVITOOLS
®
MotionStudio)
–
Programming in accordance with IEC 61131
(e.g. in LD, FBD, IL, ST, SFC)
–
MOVITOOLS
®
MotionStudio with PLC Editor,
Application Builder, etc.
–
Multi-level library concept (application and
program modules of the MOVI-PLC
®
series of
controllers)
–
PLCopen-certified motion blocks
safety
Functional safety
Safety functions integrated in the MOVIMOT
®
inverter in accordance with IEC 61800-5-2:
–
Safe disconnection (STO)
–
Safe stopping SS1(a) and SS1(c)
–
Safe motion (SDI, SLS)
–
Approval in accordance with:
- Performance level d according to EN ISO 13849-1
- SIL 2 according to IEC 61800-5-2
Safety options S11 and S12
–
PROFIsafe connection or independent operation (different numbers of safe inputs and outputs)
06