SEW EURODRIVE
224
Inverter technology
6.1 Control cabinet installation
Options for MOVITRAC
®
B and MOVIDRIVE
®
B
MOVI-PLC
®
standard controller
– DHE21B
– DHF21B
– DHR21B
– MOVI-PLC
®
standard, ETHERNET interface
– MOVI-PLC
®
standard, ETHERNET / PROFIBUS / DeviceNet
TM
interface
– MOVI-PLC
®
standard, ETHERNET / PROFINET / Modbus TCP- / EtherNet/IP
TM
interface
MOVI-PLC
®
advanced controller
– DHE41B
– DHF41B
– DHR41B
– External controller: UHX71B
– MOVI-PLC
®
advanced, ETHERNET interface
– MOVI-PLC
®
advanced, ETHERNET / PROFIBUS / DeviceNet
TM
interface
– MOVI-PLC
®
advanced, ETHERNET / PROFINET/ Modbus TCP / EtherNet/IP
TM
interface
– MOVI-PLC
®
power: IEC-61131-3 programmable motion and logic controller or
– CCU power: parameterizable application controller
MOVITOOLS
®
MotionStudio engineering
software
The MOVITOOLS
®
MotionStudio program package lets you conveniently start up, set parameters
and run diagnostics for MOVITRAC
®
B frequency inverters and MOVIDRIVE
®
B drive inverters.
Regenerative power supply
MOVIDRIVE
®
MDR60A 15 kW – 160 kW
MOVIDRIVE
®
MDR61B 160 kW – 315 kW
The regenerative power supply can supply multiple devices with power using a central line
connection. In regenerative mode, the power is fed back into the supply system. Using the
MDR60A/MDR61B saves energy and reduces installation work.
Braking resistors type BW
BW series braking resistors are available for regenerative operation of the MOVITRAC
®
B frequency
inverters and MOVIDRIVE
®
B drive inverters. Using an integrated temperature sensor, the resistor
can be protected without external monitoring.
Line choke type ND
ND series line chokes increase the overvoltage protection of inverters. This is an important charac-
teristic in rough industrial power supply systems, especially if the inverter is installed near a supply
transformer.
Line filter type NF
The NF line filter series is available for EMC-compliant installation according to EN 61800-3. They
suppress interference emissions on the line side of inverters. These line filters ensure that limit val-
ue class C1 is maintained on the supply end.
Output choke type HD
HD series output chokes suppress interference emitted from unshielded motor cables. They enable
the motor to meet limit value class C1 requirements in accordance with EN 61800-3 in EMC-com-
pliant installations. Output chokes provide an alternative to shielded motor cables in EMC-compli-
ant installations.
Output filter type HF
HF series output filters are sine filters that smooth out the output voltage of inverters. Output filters
are used for group drives to suppress discharge currents in motor cables and for long motor cables
to prevent voltage peaks.