MGM
Built-in inverter motors
54
Main Specifications
Technical Specifications
Options
Forced cooling
It allows a wider application of built-in inverter motors. It can be required at the time of the purchase or in case installed afterwards,
buying the proper kit.
Thermal protection devices
They can be inserted into the motor and controlled by the inverter logic
External potentiometer
it can be built-in (allowing the speed regulation directly on the motor)
Remote control panel
SMI motor can be also controlled through a remote keyboard. The keyboard is equipped with parameter copy function
Built-in EMI filters
Class A (industrial application)
Class B (residential application)
Braking dynamic resistance
It can be fitted in the version with vector control
Field bus
It can be arranged for the main commercial buses (Profilbus, Interbus-S, Device Net, etc.)
Power range
0.37 - 0.75 kW (single-phase) 0.75 - 15.0 kW (three-phase)
Supply voltage
1x200-240 V 50/60 (single phase)
3x380-460 V 50/60 (three-phase)
Protection class (enclosure duty)
IP 55 (IP56 on request)
Mounting
IM B3-foot mount, IM B5-flange mount, IM B14-face mount (shaft/flange reduced/increased on request)
Type of control
V/F frequency voltage control (letter x behind the motor plate)
SLV sensorless vector control (letter V behind the motor plate)
Speed adjustment range
3-150 Hz for version X (frequency voltage control)
1-150 for version V (vector control without sensor)
Analog input
0-10 V D.C. 4-20 mA
Digital input
5 programmable with 14 functions (for versions X)
6 programmable with 19 functions (for versions V)
Digital output
- 1 programmable relay - only alarm (exchange contact 250 V AC 2.5 A) version X
- 1 programmable relay with 6 functions version V
- 2 outputs with programmable transistors with 6 functions (open collector 27 V 50 mA)
Serial interface
RS 422 as standard for parameters loading/unloading
RS 485 multidrop for automation by external module
Protection functions
Over-current, over-voltage, low voltage, overloading, exceeding operation temperature, CPU error, starting phase earthed protection