MGM
Technical Data Two Speed Motor – Two Windings
BA series
Power
(kW)
RPM
In 400 V
(A)
Power
factor
Cos
ϕ
Ts/Tn
Is/In
AC
brake
In (mA)
DC
brake
In (mA)
Z
0
(starts/
hour)
Moment of
inertia
Jx 10
-4
Kgm
2
Max Brake
torque
(Nm)
A-Sound
pressure
dB(A)
Weight (Kg)
Motor type
Tn (Nm)
32
1.
Motor characteristic values reported in the tables refer
to continuous duty (S1), 50 Hz frequency, ambient temperature
max. 40
°
C, altitude up to 1000 m. above sea level operating
condition.
2.
DC brake is provided on request only on BA series motors
. Brake current consumption values refer to a rated voltage
of 3-phase 400V for
AC brakes and single-phase 230V for
DC brakes.
3.
The table shows the sound pressure noise level, measured
at one metre range from the motor according to the Acurve
(ISO 1680). The shown noise levels refer to motor no-load
operating condition and should be regarded with a tolerance
of
±
3dB.
4.
Max brake torque and Z
0
values refer to AC brake. Go to
pag. 23 for DC max brake torque values.
5.
The expressed Z
0
values refers to AC Brake. Z
0
is the
max number of no-load starts. It is meant for calculation
purposes only, and is used to obtain the max number of
starts with load according to the formula expressed at page
22. The number of starts with load (Zload) is indicative and
it has to be operatively tested for confirmation. The use of
Thermo-protectors is strongly recommended when the
operative number of starts is close to the calculated Zload.
It is necessary to verify the max permissible brake energy
dissipation and the max permissible RPM.
6.
The maximum brake torque for BAK 132 motors series
is 120Nm
BADA 80 B2/12
BADA 90 SB2/12
BADA 90 LA2/12
BADA 100 LB2/12
BADA 112 MB2/12
BADA 132 SB2/12
BADA 132 MA2/12
BADA 132 MB2/12
BADA 160 MB2/12
BADA 160 LA2/12
S3 40%
3000 / 500 r.p.m.
2 / 12 pole
BADA 180 LB2/12
0.45
0.07
0.75
0.11
1.10
0.15
1.85
0.25
3.00
0.45
4.00
0.65
5.50
0.90
7.00
1.10
8.00
1.30
11.00
1.80
15.5
22.5
23
36
45
78
87
98
154
171
16.00
2.60
243
2840
435
2800
400
2800
400
2850
410
2855
430
2880
450
2870
450
2880
450
2890
470
2890
470
2910
470
1.35
0.70
2.10
1.05
2.80
1.35
4.1
2.2
6.5
3.2
8.9
4.8
11.5
6.7
15.7
8.5
15.9
9.5
21.4
12.8
30.6
12.2
0.76
0.63
0.82
0.61
0.82
0.63
0.87
0.52
0.86
0.49
0.85
0.56
0.88
0.56
0.85
0.56
0.92
0.42
0.92
0.42
0.93
0.46
65
43
72
44
72
44
73
47
73
50
73
55
73
55
73
55
74
58
74
58
78
59
18
38
38
50
80
150
150
150
190
190
300
27.21
26.15
30.53
60.07
125.7
277.7
352.0
432.0
683.0
858.0
1740.0
1700
24000
1800
20000
1800
20000
1100
11000
1200
10000
350
2200
350
2200
350
2200
250
1200
250
1200
200
1000
150
150
150
150
470
680
680
680
860
860
1100
140
300
300
300
280
580
580
580
1390
1390
950
4.9
1.4
5.2
1.4
5.4
1.4
6.3
1.5
6.7
1.8
7.0
1.6
7.5
1.6
7.5
1.6
8.0
2.1
8.0
2.1
8.0
2.0
1.9
1.9
3.0
2.0
3.2
2.1
3.0
2.2
3.0
2.1
3.0
1.8
3.0
1.8
3.0
1.8
3.0
2.0
3.0
2.0
3.0
1.8
1.51
1.54
2.56
2.63
3.75
3.58
6.20
5.82
10.04
9.99
13.26
13.79
18.30
19.10
23.21
23.34
26.44
26.41
36.35
36.57
52.51
52.83
1500 / 375 r.p.m.
Service duty S4 (40% 4 pole – 25% 16 pole)
Motor Type
Power (kW)
RPM
Hoisting motors 4/16 pole
In 400 V (A)
AC brake In (mA)
1450 / 350
1450 / 350
1420 / 335
1420 / 330
1420 / 330
1450 / 350
1450 / 350
1470 / 360
1470 / 360
1465 / 360
1465 / 360
1465 / 360
7.3 / 5.1
10.8 / 7.6
11.6 / 8.0
16.2 / 11.4
22.2 / 15.9
25.0 / 21.7
31.5 / 27.4
38.2 / 28.0
47.3 / 34.7
58.7 / 43.3
78.3 / 57.7
97.9 / 72.2
580
580
1390
1390
1390
950
950
1350
1350
2000
2000
2000
BAPKDA 132 MA4/16
BAPKDA 132 MB4/16
BAPKDA 160 MA4/16
BAPKDA 160 MB4/16
BAPKDA 160 LB4/16
BAPKDA 180 LA4/16
BAPKDA 200 LB4/16
BAPKDA 225 S4/16
BAPKDA 225 M4/16
BAPKDA 250 M4/16
BAPKDA 280 S4/16
BAPKDA 280 M4/16
2.8 / 0.7
4.0 / 1.1
5.5 / 1.3
7.3 / 1.8
10.0 / 2.5
13.2 / 3.0
16.0 / 4.0
19.0 / 4.8
24.0 / 6.0
30.0 / 7.5
40.0 / 10.0
50.0 / 12.5