LENZE
2
Drive selection
AC asynchronous motor (inverter-optimised)
2-54
Small drives en 07/2010
Selection table Type SDSGA
òò
0
òò
-
ò
2
P
N
100 Hz
Design
Selection
Motor type
n
2
M
2
A-side
(tick as required)
W
rpm
Nm
SDSGA
òò
047-22
75
2700
0.27
IEC56 B14 C80
SDSGA
òò
056-22
240
2790
0.81
IEC63 B14 C90
SDSGA
òò
063-22
400
2800
1.35
IEC71 B14 C105
SDSGA
òò
063-32
600
2825
1.90
IEC71 B14 C105
Rated voltage
230 V
connector version and motor frame size 047 only
390 V
connector version and motor frame size 056-063 only
230/400 V
terminal box version only
Enclosure
IP54
IP55
Motor protection
KTY
connector version only
Thermal contact 'NC contact'
terminal box version only
Electrical connection
Terminal box
Connector
B-side design
XX=no built-on accessories
terminal box version only
RS=with resolver
connector version only
BR=with spring-applied brake
terminal box version only
RS=with incremental encoder
connector version only
BS=with spring-applied brake and resolver
connector version only
BI=with spring-applied brake and incremental encoder
connector version only
BV=for brake attachment
terminal box version only
Brake supply voltage
24 V DC
230 V AC with bridge rectifier
terminal box version only
Position of electrical connection
2
Additional order information
Type code see pages 1-3 to 1-6.
Mounting position see cover fold-out.