LENZE
2
Drive selection
Technical data AC asynchronous motors (inverter-optimised)
2-46
Small drives en 07/2010
Parameter setting for servo inverter 9321
Code
Setting
Meaning
Y
Δ
C0006
2
22
Servo asynchronous
C0025
RsX
Resolver
C0070
5
C0071
150
ms
C0075
0.35
C0076
1.80
ms
C0081
0.60
Pn (kW)
C0084
8.5
Rphase (ohm)
C0085
26
Xleakage (mH)
C0086
0
COMMON
C0087
2825
nn (rpm)
C0088
1.74
3
In (A)
C0089
100
fn (Hz)
C0090
390
230
Un (V)
C0091
0.70
cos phi
Connector for resolver and thermal contact
Pin no.
Connection name
Connection to:
1
+Ref
Resolver
2
-Ref
Resolver
3
4
+cos
Resolver
5
-cos
Resolver
6
+sin
Resolver
7
-sin
Resolver
8
9
10
11
+
KTY/thermal switch
12
-
KTY/thermal switch
Connector for motor and brake
Pin no.
Connection name
Connection to:
1
Y1
Brake
2
Y2
Brake
PE
PE
Conductor
4
U
Motor phase
5
V
Motor phase
6
W
Motor phase
Connection plan for inverter motor SDSGA
ò
063-32
Encoder connector
for resolver/
Encoder angular
Incremental encoder
connection
Motor angular
Power connector
connection
Connector for incremental encoder and thermal contact
Pin no.
Connection name
Connection to:
1
B
Track B
2
-A
Track A inv.
3
A
Track A
4
+UB
+5 V - +24 V
5
+-0V
Grnd
6
-N
Track 0 inv.
7
N
Track 0
8
9
-B
Track B inv.
10
11
+
KTY/thermal switch
12
-
KTY/thermal switch