LENZE
2
Drive selection
Technical data AC asynchronous motors (inverter-optimised)
2-43
Small drives en 07/2010
Parameter setting for servo inverter 9321
Code
Setting
Meaning
Y
Δ
C0006
2
22
Servo asynchronous (Y)
C0025
RsX
Resolver
C0070
5
C0071
150
ms
C0075
0.35
C0076
1.80
ms
C0081
0.075
Pn (kW)
C0084
72
Rphase (ohm)
C0085
267
Xleakage (mH)
C0086
0
COMMON
C0087
2700
nn (rpm)
C0088
0.52
0.90
In (A)
C0089
100
fn (Hz)
C0090
390
230
Un (V)
C0091
0.5
cos phi
Connector for resolver and thermal contact
Pin no.
Connection name
Connection to:
1
+Ref
Resolver
2
-Ref
Resolver
3
4
+cos
Resolver
5
-cos
Resolver
6
+sin
Resolver
7
-sin
Resolver
8
9
10
11
+
KTY/thermal switch
12
-
KTY/thermal switch
Connector for motor and brake
Pin no.
Connection name
Connection to:
1
Y1
Brake
2
Y2
Brake
PE
PE
Conductor
4
U
Motor phase
5
V
Motor phase
6
W
Motor phase
Connection plan for inverter motor SDSGA
òò
047-22
Encoder connector
for resolver/
Encoder angular
Incremental encoder
connection
Motor angular
Power connector
connection
Connector for incremental encoder and thermal contact
Pin no.
Connection name
Connection to:
1
B
Track B
2
-A
Track A inv.
3
A
Track A
4
+UB
+5 V - +24 V
5
+-0V
Grnd
6
-N
Track 0 inv.
7
N
Track 0
8
9
-B
Track B inv.
10
11
+
KTY/thermal switch
12
-
KTY/thermal switch