LENZE
General data
Motor type
SDSGA
òò
0
òò
-
òò
Enclosure
IP54 or IP 55
Thermal class (VDE530)
F
Motor protection
Thermal contact or KTY
Note options in the tables
Cooling
Naturally ventilated
Temperature range
-20 to +40 °C
Site altitude
Up to 1000 m a.m.s.l.
Electrical connection
Connector or terminal box
Note options in the tables
Bearing
Deep-groove ball bearing
Operating mode (VDE530)
S1
Description
Inverter-optimised motors are characterised by their
smooth surface and variable applications.
The reinforced insulation system is particularly dimensio-
ned for inverter operation.
2
Drive selection
Technical data AC asynchronous motors (inverter-optimised)
2-42
Small drives en 07/2010
Rated data
Motor type
SDSGA
òò
047-22
SDSGA
òò
056-22
SDSGA
òò
063-22
SDSGA
òò
063-32
Rated power (W)
75
240
400
600
Rated torque (Nm)
0.27
0.81
1.35
1.9
Rated current (A)
0.90/0.52
1.49/0.86
2.02/1.23
3.00/1.74
Rated voltage (V)
230/400
230/400
230/400
230/400
Rated frequency (Hz)
100
100
100
100
Rated speed (rpm )
2700
2790
2800
2825
Max. speed (rpm )
6000
6000
6000
6000
Power factor
0.5
0.714
0.7
0.7
Moment of inertia (kgcm
2
)
0.41
1.404
2.796
4.21
Max. radial force (N) F
r
350
560
650
650
Max. axial force (N) F
a
750
430
510
510