LENZE
Rated data for axis modules
Rated data for operation at 3/PE/AC 480 V
DS_GD_ECS_0003
Available for download at
ƒ
The data is valid for operation at 3/PE AC 400 V.
ƒ
Unless otherwise specified, the data refers to the default
setting with a switching frequency of 8/4 kHz.
Product key
ECS
☐
x032
ECS
☐
x016
ECS
☐
x008
ECS
☐
x004
Axis modules
DC supply
DC 0 V 0% ... 770 V + 0%
U
DC
[V]
Rated DC-bus current
15.6
9.8
4.9
2.5
I
DC
[A]
Rated output current
12.7
1)
8
4
2
I
N
[A]
4 kHz
8.5
1)
5.3
2.7
1.35
I
N
[A]
8 kHz
Max. output current
32
16
8
4
I
max
[A]
Inverter
Max. short-term output current
32
16
8
4
I
max
[A]
Power loss
27.5
20.7
17.3
13.3
P
V
[W]
Module interior
117
64
29
14
P
V
[W]
Heatsink
Integrated DC-bus capacity
165
C
[uF]
Dimensions
247
H
[mm]
Height
287
H
[mm]
Height "cold plate"
88
B
[mm]
Width
176
T
[mm]
Depth
121
T
[mm]
Depth "cold plate"
Mass
2.2
m
[kg]
Permissible motor cable length
50
l
[m]
Shielded
2)
100
l
[m]
Unshielded
2)
26% - 35% higher output current possible depending on the control factor.
1)
Permissible cable length may be affected if EMC conditions have to be met.
2)
Dimensioned drawings for "cold plate" axis modules
DS_MB_ECS_0004
Available for download at
Dimensioned drawings for power supply modules
DS_MB_ECS_0001
Available for download at
Servo inverters en 03/2009
†
50
ECS servo system
Axis modules