LENZE
Rated data for axis modules
Rated data for operation at 3/PE/AC 480 V
DS_GD_9300_0003
Available for download at
ƒ
The data is valid for operation at 3/PE AC 400 V.
ƒ
Unless otherwise specified, the data refers to the default
setting with a switching frequency of 8 kHz.
Motor power
3
1.5
0.75
0.37
P
N
[kW]
(asynchronous motor, 4-pole)
Product key
EVS9324-E
☐
EVS9323-E
☐
EVS9322-E
☐
EVS9321-E
☐
Mains voltage range
3/PE AC 320 V -0% … 528 V +0%; 45 Hz -0% … 65 Hz +0%
U
Netz
[V]
Alternative DC supply
DC 460-0% … 740 V+0%
U
DC
[V]
Rated mains current
7
3.9
2.5
1.5
I
Netz
[A]
With mains choke
1)
-
5.5
3.5
2.1
I
Netz
[A]
Without mains choke
1)
Rated output current
7.0 / 4.9
2)
3.9 / 2.7
2)
2.5 / 1.75
2)
1.5 / 1.05
2)
I
N
[A]
8 kHz
5.2 / 3.64
2)
2.9 / 2.03
2)
1.8 / 1.26
2)
1.1 / 0.77
2)
I
N
[A]
16 kHz
Max. output current
10.5
5.9
3.8
2.3
I
max
[A]
8 kHz
7.8
4.35
2.7
1.65
I
max
[A]
16 kHz
Brake chopper data
11, depending on the external brake resistor
P
[kW]
Continuous braking power
25
P
BRmax
[kW]
Peak braking power
27 ± 10%
R
[Ohm]
Min. brake resistance
Power loss
200
140
110
100
P
V
[W]
Dimensions
350
H
[mm]
Height
97
78
B
[mm]
Width
250
T
[mm]
Depth
158
T
[mm]
Depth "cold plate"
Mass
5
4
m
[kg]
Permissible motor cable length
50
l
[m]
Shielded
Without mains filter
1)
Operating mode acceleration drive: The maximum overcurrent duration is
10 s at 50 s base load duration at max. 44% INx.
2)
Dimensioned drawings for "cold plate" axis modules
DS_MB_9300_0004
Available for download at
Dimensioned drawings for axis modules
DS_MB_9300_0001
Available for download at
Servo inverters en 03/2009
†
22
9300 servo inverter
Axis modules