LENZE
Wiring terminals
Wiring terminals allow mains or control cables to be looped
through and wired in the carrier housing of the 8200 motec.
A "power bus" can be set up in conjunction with the mains
bus connectors.
Systemterminalsareperfectforconnectingandwiringcontrol
cables.
ƒ
3 ... 7.5 kW:
Wiring terminals E82ZWKN4 and E82ZWKN2
When using standard twin wire end ferrules, mains cables
of up to 4mm
2
can be rounded in the motec carrier hous-
ing.
Product key
Design
E82ZWKN2
Mains bus connector
0.25 … 0.37 kW (max. 16A)
E82ZWKN4
Mains bus connector
0.55 … 2.2 kW (max. 24A)
E82ZWKS
System terminals (12-pole)
0.55 … 2.2kW
1)
System terminals cannot be used in combination with bus I/O or brake switch
1)
Current limiting module
A current limiting module reduces the current peak when the
8200 motec(s) is (are) started up on the mains supply. The
module is designed for DIN rail mounting.
Current limiting module
Product key
Design
E82ZJ004
2)
Current limiting module
0.25 … 2.2 kW (max. 20A)
At 0.55 … 2.2kW: use 3 items
2)
Data sheet on current limiting module
DS_ZB_SBM_0001
Available for download at
Frequency inverter en 02/2009
†
96
8200 motec frequency inverter
Accessories