LENZE
Standards and operating conditions
Conformity
CE: Low-Voltage Directive (2006/95/EC)
Approvals
Power Conversion Equipment (file no. 132659)
UL 508C
Enclosure
IP65
EN 60529
(IP54 for 3.0 … 7.5 kW with fan module E82ZMV)
Protection against accidental contact according to NEMA 250 type
4 (type 12)
NEMA
Climatic conditions
1K3 (temperature: -25°C ... + 60°C)
Storage (EN 60721-3-1)
2K3 (temperature: -25°C ... + 70°C)
Transport (EN 60721-3-2)
3K3 (temperature: -20°C … + 60°C)
Operation (EN 60721-3-3)
above + 40°C by 2.5%/°C
Rated output current derating
Permissible installation height
0 ... 4000 m amsl
Above 1000 m amsl by 5%/1000 m
Rated output current derating
Vibration resistance
Acceleration resistant up to 2 g according to Germanischer Lloyd,
general conditions
Permissible supply forms
Operation on TT systems, TN systems or systems with earthed
neutral without additional measures
Operation on IT systems not possible
The devices are approved only for operation on symmetrical sys-
tems. Operation on systems with earthed phase conductor is not
permitted.
Leakage current to PE
> 3.5 mA
EN 61800-5-1
Noise emission
Cable-guided, category C2 up to 1 m shielded motor cable: with
integrated RFI measures
1)
EN 61800-3
Cable-guided, category C2 up to 10 m shielded motor cable: with
integrated RFI measures
1)
Noise immunity
Category C3
EN 61800-3
Insulation resistance
Overvoltage category III,
EN 61800-5-1
more than 2000 m above sea level overvoltage category II
Pollution degree
2
EN 61800-5-1
Protective insulation of control circuits
Safe isolation of mains: double/reinforced insulation
EN 61800-5-1
Motor cable lengths depend on inverter type and switching frequency
1)
Frequency inverter en 02/2009
†
90
8200 motec frequency inverter
Product information