KSB
Pumps
Pumps
64
WKTB
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
n [rpm]
150 – 300
max. 1500
max. 370
max. 40
max. +140
1500
Description:
Vertical can‐type ring‐section pump, underfloor installation on base
frame, multistage, first‐stage impeller designed as a double‐entry suction
impeller, radial impellers. Flanges to DIN or ANSI.
Applications:
For pumping condensate in power stations and industrial plants.
Data for 50 Hz operation
Higher ratings possible upon request.
SEZ / SEZT / PHZ / PNZ
Q [m
3
/h]
H [m]
T [°C]
n [rpm]
max. 80000
max. 120
max. +40
max. 980
Description:
Vertical tubular casing pump with open mixed flow impeller (SEZ), mixed
flow propeller (PHZ) or axial propeller (PNZ), pump inlet with bellmouth
or suction elbow, pull‐out design available, discharge nozzle arranged
above or below floor level, flanges to DIN or ANSI standards available.
Applications:
For pumping raw, clean, service and cooling water in industry, water
supply systems, power stations and seawater desalination plants.
Data for 50 Hz operation
Also available for 60 Hz
Higher ratings possible upon request.
SNW / PNW
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
n [rpm]
350 – 800
max. 9000
max. 50
max. 10
max. +60
max. 1500
Description:
Vertical tubular casing pump with mixed flow impeller (SNW) or axial
propeller (PNW), single‐stage, with maintenance‐free Residur bearings,
discharge nozzle arranged above or below floor level.
Applications:
Irrigation and drainage systems, stormwater pumping stations, pumping
raw and clean water, water supply, cooling water.
Data for 50 Hz operation
Also available for 60 Hz
Higher ratings possible upon request.
Beveron
Q [m
3
/h]
H [m]
max. 30
max. 27
Description:
Concrete volute casing pump with mixed flow impeller, single‐stage, with
zero‐maintenance lubricant‐free Residur bearings.
Applications:
Coast protection and flood control, irrigation and drainage, low‐lift
pumping stations, reservoir filling, cooling water, raw and clean water.
Data for 50 Hz operation
Also available for 60 Hz
Higher ratings possible upon request.
SPY
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
n [rpm]
350 – 1200
max. 21600
max. 50
max. 10
max. +105
max. 1480
Description:
Long‐coupled volute casing pump, single‐stage, in back pull‐out design.
Applications:
Irrigation, drainage and water supply systems, for pumping condensate,
cooling water, service water, etc.
Data for 50 Hz operation
Also available for 60 Hz
Higher ratings possible upon request.
Not available for worldwide sale
Factory‐automated
Automation possible