KSB
Pumps
Pumps
61
Axially split pumps
Omega
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
n [rpm]
80 – 350
max. 2880
max. 210
max. 25
max. +140
max. 3500
Description:
Single‐stage axially split volute casing pump for horizontal or vertical
installation, with double‐entry radial impeller, mating flanges to DIN, EN
or ASME.
Applications:
For pumping water with a low solids content, e.g. in waterworks,
irrigation and drainage pumping stations, extraction duties in
desalination systems, power stations, fire‐fighting systems, shipbuilding,
district heating or cooling.
Data for 50 Hz and 60 Hz operation
Higher ratings possible upon request.
PumpMeter, PumpDrive
RDLO
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
n [rpm]
350 – 700
max. 10000
max. 240
max. 25
max. +140
max. 1800
Description:
Single‐stage axially split volute casing pump for horizontal or vertical
installation, with double‐entry radial impeller, mating flanges to DIN, EN
or ASME.
Applications:
For pumping water with a low solids content, e.g. in waterworks,
irrigation and drainage pumping stations, extraction duties in
desalination systems, power stations, fire‐fighting systems, shipbuilding,
district heating or cooling.
Data for 50 Hz and 60 Hz operation
Higher ratings possible upon request.
PumpMeter, Frequency inverter
RDLP
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
n [rpm]
350 – 1200
max. 18000
max. 550
max. 64
max. +80
max. 1800
Description:
Axially split volute casing pump for horizontal installation, with one, two
or three stages and double‐entry radial impeller, mating flanges to DIN,
ISO or ANSI.
Applications:
For pumping water with a low solids content, e.g. in waterworks and
long‐distance water supply.
Data for 50 Hz and 60 Hz operation
Higher ratings possible upon request.
PumpMeter, Frequency inverter
Hygienic pumps
Vitachrom
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
50 – 125
max. 340
max. 100
max. 12
max. +140
Description:
Service‐friendly non‐priming, close‐coupled single‐stage hygienic pump in
back pull‐out design. The pump features a semi‐open impeller and
electropolished surfaces. It is very easy to clean by CIP/SIP thanks to its
almost complete lack of dead volume or narrow clearances. Its wetted
components are made of 1.4404/1.4409 (AISI 316L/CF3M) stainless steel.
Vitachrom is EHEDG‐certified. All materials comply with FDA standards
and EN 1935/2004. ATEX‐compliant version available.
Applications:
Hygienic handling of fluids in the food, beverage and pharmaceutical
industries and in the chemical industry.
Data for 50 Hz operation
Also available for 60 Hz
PumpDrive, KSB SuPremE