KSB
Pumps
Pumps
35
Seal‐less pumps
Magnochem
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
25 – 250
max. 1160
max. 162
max. 40
‐90 to +300
Description:
Horizontal, seal‐less volute casing pump in back pull‐out design, with
magnetic drive, to DIN EN ISO 2858 / ISO 5199, with radial impeller, single‐
entry, single‐stage. ATEX‐compliant version available.
Applications:
For pumping aggressive, toxic, explosive, valuable, flammable,
malodorous or harmful liquids in the chemical, petrochemical and general
industries.
PumpMeter, PumpDrive, KSB SuPremE
Magnochem‐Bloc
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
25 – 160
max. 754
max. 162
max. 25
max. +200
Description:
Horizontal, seal‐less volute casing pump in close‐coupled design, with
magnetic drive, to DIN EN ISO 2858 / ISO 5199, with radial impeller, single‐
entry, single‐stage. ATEX‐compliant version available.
Applications:
For pumping aggressive, toxic, explosive, valuable, flammable,
malodorous or harmful liquids in the chemical, petrochemical and general
industries.
PumpMeter, PumpDrive
Etaseco / Etaseco‐I
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
32 – 100
max. 250
max. 162
max. 16
max. +140
Description:
Horizontal or vertical seal‐less volute casing pump in back pull‐out design
with fully enclosed canned motor, low noise emission, with radial
impeller, single‐stage, single‐entry, casing connecting dimensions to
EN 733.
Applications:
For pumping aggressive, flammable, toxic, volatile, or valuable liquids in
the chemical and petrochemical industries, in environmental engineering
and industrial applications.
PumpMeter, PumpDrive
Etaseco RVP
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
32
max. 20
max. 25
max. 10
max. + 85
Description:
Horizontal or vertical seal‐less volute casing pump in back pull‐out design
with fully enclosed canned motor, low noise emission, with radial
impeller, single‐stage, single‐entry.
Applications:
For pumping toxic, volatile or valuable liquids in environmental
engineering and industrial applications and as coolant pump in cooling
systems. Transport vehicles, environmental engineering and industry;
applications where low noise emission, smooth running or long service
intervals are required.
PumpMeter, PumpDrive
Secochem Ex
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
25 – 100
max. 300
max. 150
max. 25
max. +130
Description:
Horizontal seal‐less volute casing pump in back pull‐out design with fully
enclosed canned motor, low noise emission, with radial impeller, single‐
stage, single‐entry, casing connecting dimensions to EN 22858 / ISO 2858.
ATEX‐compliant version available.
Applications:
For pumping aggressive, flammable, explosive, toxic, volatile or valuable
liquids in the chemical and petrochemical industries, in environmental
engineering and industrial applications.
PumpDrive, Frequency inverter